When your HydroFlame 8500 series furnace shuts off unexpectedly or won't ignite, a failed high-temperature limit switch is one of the most common culprits. The Atwood 37022 is a direct-fit 190F limit switch engineered to restore safe, reliable furnace operation -- no modification required. This is the same switch the furnace shipped with, sourced as NBK part number 20297.
The high-temperature limit switch is a critical safety component inside your RV furnace. It monitors heat exchanger temperature and cuts power to the burner if temperatures climb above the rated threshold -- protecting the furnace and your rig from overheating damage. When the switch fails (open circuit) the furnace will lock out even at normal operating temperatures, mimicking an ignition or airflow problem.
Atwood part 37022 (also listed as NBK 20297) is a 190-degree Fahrenheit bi-metal limit switch designed as an exact replacement for the furnace models listed below. If your HydroFlame 8500 series furnace is shutting down on limit, failing to ignite, or showing a limit lockout fault, inspect this switch before replacing costlier components.
Rated to open the circuit at 190 deg F, matching the original factory specification for 8500 series furnace heat exchanger protection.
Designed to replace the original Atwood 37022 without wiring changes or bracket modification. Fits the existing mounting location and connector.
Compatible with 8516, 8520, 8525, 8531, and 8535 furnaces in both III and IV configurations, plus 1522 and 2334 two-stage models.
Weighs approximately 0.5 lbs. Easy to carry as a spare for full-timers and extended-season campers who can't afford furnace downtime.
The limit switch is a normally closed bi-metal safety device wired in series with the furnace control circuit. Under normal operation the switch remains closed and current flows freely. If the heat exchanger temperature reaches 190 deg F -- caused by blocked airflow, a dirty filter, a failed blower motor, or another fault -- the bi-metal disc snaps open and interrupts the circuit, shutting down the burner. Some switches auto-reset on cooldown; others latch open and require manual reset or replacement. If your furnace is consistently tripping the limit, address the root cause (airflow restriction, blower performance) before fitting the new switch.
Verify your furnace model number on the data plate inside the furnace access door before ordering. This switch fits the following HydroFlame models:
A high-temp limit switch that trips repeatedly is usually a symptom, not the root cause. Before installing the new switch, check the following: