Fasco 8710-4358 replacement blower wheel, 4-3/4" dia x 1-3/4" wide, 5/16" bore, 3600 RPM, counter-clockwise rotation. Fits Fasco A136, A137, A142, A165, A168, A224, A227, and others.
Goodman OEM-spec replacement condenser fan motor. 208-230V, 60Hz, 35W, 1350/1170 RPM, counter-clockwise rotation, Class B insulation. Replaces 0131P00025 and 0131P00025S.
Dayton 1TDP2 replacement blower motor, 104 CFM, 2815 RPM, 115V/60Hz, 1.25A, Class B, ball bearings, clockwise rotation. Replaces Dayton 4C763. Also known as NBK 20495.
Dayton 1TDN4 replacement blower motor, 49 CFM, 3080 RPM, 115V/60Hz, 0.50A, Class B, ball bearings, clockwise rotation. Replaces Dayton 4C761. Also known as NBK 20660.
Dayton 1TDP6 replacement blower motor, 133 CFM, 2670/2880 RPM, 230V, 50/60 Hz. Replaces Dayton 2C915 and 1TDP6A. Ball bearings, Class B insulation, 6 lbs.
The Dayton Replacement Blower Motor is designed to replace JA1C182, 7021-3506, Dayton 2C914, or AO Smith/Century 9443. 49 cubic ft per minute, 2700/3080 RPM. 230 volts.
Dayton 1TDU9 replacement blower motor, 76 CFM, 2680/3020 RPM, 115V, 50/60 Hz. Ball bearing construction, Class B insulation. Direct replacement for Dayton 4C940. Also known as NBK 20534.
Fasco A182 replacement draft inducer blower motor, 115V, 3000 RPM, 1/35 HP. Direct replacement for Fasco 7002-3036, Emerson 3105, Amana B4059000, and Goodman B4059000.
Fasco A164 draft inducer blower motor, 115V, 3000 RPM, 0.34A. Replaces Fasco 7021 series and Lennox 46K4101, 67M5401, and related models. UL/CSA listed. NBK 12165.
Dayton 1TDP8 replacement blower motor, 184 CFM, 2750/3150 RPM, 115V, 50/60 Hz. Ball bearings, auto overload protection. Replaces Dayton model 4C015.
Fasco D219 -- 1/8 HP, 115V, 3000 RPM, 3.3" frame PSC blower motor. Thermally protected, totally enclosed, reversible rotation. Capacitor included. Also NBK 20608.
Dayton 1TDP4 replacement blower motor. 71 CFM, 1580 RPM, 115V, 0.50A, ball bearings, clockwise rotation. Direct replacement for Dayton model 2C067. Also listed as NBK Parts 20496.
Dayton 1TDP3 replacement blower motor, 75 CFM, 3020 RPM, 115V, 0.45A. Replaces Dayton 4C443 and Fasco 7021-4931. Ball bearings, auto overload, 4-in outlet flange.
The Dayton Replacement Blower motor is designed to replace Fasco model 7021-6560. 115 cubic ft per minute, 2800/3200 RPM. 115 volts.
Fasco A983 replacement exhaust vent blower for Intercity furnaces. 115V, 3000 RPM, 1/45 HP, 1.87A, CCWSE rotation, ball bearings, UL and CSA listed. Replaces 119290-00, 1014433, 1014529, 70582726.
Dayton 1TDR1 replacement blower motor, 168 CFM, 1400/1650 RPM, 115V, Class B, ball bearings, clockwise rotation. Direct drop-in for Dayton 2C916. Also sold as NBK 20514.
Dayton 1TDR6 blower motor, 150 CFM, 2450/2480 RPM, 115V, 50/60 Hz. Replaces Dayton 4C006. Ball bearings, Class B insulation, auto overload protection. NBK part 20516.
Fasco A079 draft inducer blower motor, 115V, 2420/2500 RPM. Replaces Rheem, York, Nordyne, Goodman, Trane, and Packard part numbers. UL and CSA listed.
Fasco A169 draft inducer blower motor, 230V, 1/25 HP, 3060 RPM, 3.3" diameter. Replaces ICP 1085571, Fasco 7021-10048, Emerson 3114, and more. UL/CSA listed.
Fasco A217 draft inducer blower motor, 208-230V, 3000 RPM, 0.36A. Direct replacement for Lennox 25M5501 and Fasco 7021-11231. Ball bearing, Class B insulation, built-in thermal protection.
Dayton 1TDR9 replacement blower motor, 463 CFM, 1520 RPM, 115V/60Hz, 1.21A. Replaces Dayton 4C264 and 4C448. Ball bearings, Class B insulation, auto overload protection. Also sold as NBK 20520.
NBK Parts 20751 blower motor replaces Fasco 7063-7161. 227 CFM, 1430/1700 RPM, 115V, 1/30 HP, PSC motor with ball bearings and automatic overload protection.
Dayton 1TDU7 replacement blower motor. 127 CFM, 3235 RPM, 115V/60Hz, 0.32A, Class B insulation, ball bearings, auto overload protection. Replaces Dayton 4C825.
Fasco A143 draft inducer blower motor, 115V, 3000 RPM, 1/50 HP. Direct replacement for Trane, Emerson, Jakel, and Mars furnace models. Thermally protected with ball bearing construction.
Dayton 1TDR4 replacement blower motor, 271 CFM, 1380/1620 RPM, 230V, 50/60 Hz. Replaces Dayton 4C869. Ball bearings, auto overload, clockwise rotation. NBK 20515.
US Motors 5462H PSC condenser fan motor, 208-230V, 1075 RPM, 1/6-1/3 HP, 5.6" diameter, TEAO enclosure, reversible rotation, 48" leads. Also listed as NBK 20587.
Dayton 1TDT6 replacement 2-speed blower motor. 428/293 CFM, 1500/1085 RPM, 115V, 1.1A. Ball bearings, CCW rotation. Replaces Dayton 4C565. Also known as NBK 20500.
Fasco A150 replacement draft inducer blower motor for Fasco and Trane furnaces. 208-230V, 3000 RPM, 3.3" diameter, ball bearings, UL/CSA listed. Also known as NBK 12178.
Dayton 1TDU8 blower motor replaces Dayton 4C826. 223 CFM, 2600/2750 RPM, 115V, 50/60 Hz. Ball bearings, Class B insulation, auto overload protection. Also listed as NBK 20533.
Fasco A206 replacement draft inducer blower motor, 115V, 2850/3300 RPM. Replaces Fasco 70218473, 70218983 and Lennox 20J8901, 65204100. Also known as NBK 12177.
Fasco A163 replacement 120V draft inducer blower motor, 3400 RPM, 1/20 HP, 1.93A, 3.3 in. diameter. Replaces Lennox, Emerson, and Fasco OEM part numbers. NBK 20209.
Dayton 1TDR8 replacement blower motor, 358 CFM, 1350/1530 RPM, 230V, 50/60 Hz. Direct replacement for Dayton 2C917. Ball bearings, clockwise rotation, Class B insulation.
US Motors 5470 PSC direct drive blower motor, 3/4 HP, 115V, 1075 RPM, 4-speed, 9.8A, reversible, ball bearings, ring/stud mount for commercial and residential HVAC systems.
Dayton 1TDR5 blower motor, 312 CFM, 1280/1380 RPM, 115V, 50/60 Hz. Direct replacement for Dayton 2C069. Ball bearings, Class B insulation, auto overload protection. 6 lbs.
Dayton 1TDV4 blower motor, 310 CFM, 1400/1640 RPM, 115V, 50/60 Hz. Replaces Fasco 7090-2379 and 7064-1678. Ball bearings, Class B insulation, auto overload protection.
Dayton 1TDT3 replacement blower motor. 559 CFM, 1420 RPM, 230V, 0.97A, 60 Hz, Class B insulation, ball bearings, clockwise rotation. Replaces Dayton 4C870.
US Motors 5464H PSC condenser fan motor, 208-230V, 825 RPM, 1/6-1/3 HP, TEAO enclosure, 5.6in diameter, reversible, 2-speed, ball bearings, continuous duty.
Dayton 1TDT8A 2-speed replacement blower motor. 797/549 CFM, 1360/970 RPM, 115V, 3.3A. Replaces Dayton 5C508, Fasco 7090-1184, and Century 9459. Ball bearings, auto overload protection.
Fasco A173 / NBK 12181 draft inducer motor, 115V, 3450 RPM, 1/18 HP, PSC, ball bearing. Replaces Fasco 7062-4785, ICP 1011350, Mars 74417, and related models.
Fasco A330 draft inducer blower motor, 3.3in diameter, 208-230V, 2700/3200 RPM, PSC, ball bearing. Replaces Fasco 7062-4083 and Lennox 69M3301, 97J8201.
Dayton 1TDT2 replacement blower motor -- 549 CFM, 1330 RPM, 115V, 2.2A, ball bearings, Class B. Replaces 4C445, 2C906, 2C962, 4C667, 4YJ32. Also listed as NBK 20499.
NBK Parts 20503 is a direct-replacement 2-speed inducer fan blower motor for Carrier, Bryant, and Payne furnaces. 115V/60Hz, 3175/1500 RPM, 4.85 lbs. Replaces 326628-763, HC21ZE122A, and more.
Dayton 1TDT7 replacement 2-speed blower motor. 542/409 CFM, 1380/1045 RPM, 115V, 2.0A, ball bearings, CW rotation. Replaces Dayton 4C565 (NBK 20501).
Fasco A331 replacement draft inducer blower motor. 3.3" dia., 460V, 2800/3200 RPM, PSC, ball bearings. Replaces Lennox 69M3201, 97J8101, Fasco 7062-4051 and more.
Packard 66756 replacement draft inducer blower motor for select Carrier and ICP furnaces. 115V, 3300 RPM, 1/12 HP, 58W PSC motor with capacitor and Molex plug included.
Fasco A324 replacement draft inducer blower motor for select Fasco and Lennox furnaces. 230V, 0.38A, 3400 RPM, PSC motor with ball bearing and Class B insulation.
Packard 82113 replaces Carrier HC45TE113 and GE 5KCP39PGV623CS. 3/4 HP, 115V, 9.2A, 1075 RPM, 3-speed, ball bearing, 4-leg torsion flex mount, open enclosure.
Fasco A273 draft inducer blower motor, 3.3" diameter, 208-230V, 3417 RPM, 0.64A. Replaces Fasco 7062-3972 and Trane 38040310. UL and CSA listed.
Packard 66649 replacement PSC draft inducer motor for select Carrier and ICP furnaces. 208-230V, 3450 RPM, 58W. Capacitor included. Does not include housing.
Packard 66755 replaces Carrier 309868755. PSC draft inducer motor, 115V, 0.86A, 3300 RPM, 1/20 HP. Includes capacitor, blower wheel, bracket, and lead adapters.
Packard 66757 draft inducer blower motor for Carrier furnaces. 115V, 3000 RPM, 58W PSC, 3-inch inlet, ball bearing, capacitor included. Replaces Carrier 320725757.
Packard 66758 drop-in replacement draft inducer blower motor for select Carrier furnaces. 115V, 3400 RPM, 58W PSC with capacitor and Molex plug included.
Dayton 1TDT4 blower motor, 805 CFM, 910/1030 RPM, 115V, 2.6/2.8A. Replaces Dayton 2C946 and NBK 20519. Ball bearings, Class B insulation, auto overload protection.
Dayton 1TDU1 replacement blower motor, 990 CFM, 920/1050 RPM, dual voltage 115/230V, 50/60 Hz. Replaces Dayton 4C830. Ball bearings, auto overload protection.
Fasco 7190-2773 double-shaft fan motor, 115V single phase, 1100 RPM, 3.5A. Direct replacement for Greenheck part 304970. Open enclosure, sleeve bearings, Class B insulation.
Dayton 1TDT9 replacement blower motor, 794 CFM, 1030 RPM, dual voltage 115/230V, Class B, ball bearings, clockwise rotation. Replaces Dayton 4C668. Also listed as NBK 20502.
Dayton 1XJX7 replacement blower motor assembly, 1009 CFM, 1070 RPM, 115V, 1/6 HP. Includes motor, housing, and 9-3/8 in blower wheel. Ball bearings, clockwise rotation.
Dayton 1TDU2 replacement blower motor, 1202 CFM, 1320/1380 RPM, 115/230V, 50/60 Hz. Replaces Dayton 4C831. Ball bearings, Class B insulation, auto overload protection. NBK 20531.
NBK Parts 20832 direct-replacement exhaust inducer motor for Carrier furnaces. 208/230V, 3450 RPM, 0.47A, 60Hz. Replaces Carrier 1171314, HC30GB232, Packard 66815, and more.
Our blower motors are designed specifically for RV applications, built to withstand the unique demands of mobile living while providing reliable, quiet operation. These motors power the fans and blowers that move air through your RV's HVAC system, ensuring proper airflow for optimal comfort year-round.
RV Furnace Blower Motors:
Combustion Air Blowers - Essential motors that provide fresh air to the furnace combustion chamber, ensuring proper burning and safe operation. These motors typically run at lower speeds and are designed for continuous duty cycles during heating operation.
Convection Air Blowers - High-volume motors that circulate heated air throughout your RV's interior. These larger motors move the warm air from the heat exchanger through your ductwork to living spaces, bedrooms, and bathrooms.
Compatible Brands - Direct replacements for Atwood, Dometic, Suburban, Coleman, and Hydro Flame furnace systems. Motors are matched to specific model numbers to ensure proper fit, airflow, and electrical compatibility.
AC System Motors:
Condenser Fan Motors - Outdoor motors that pull air through the condenser coils on your rooftop AC unit. These motors operate in harsh conditions including heat, UV exposure, and weather, requiring durable construction and reliable performance.
Evaporator Blower Motors - Indoor motors that circulate cooled air through your RV's interior. Available in single-speed and multi-speed configurations to match your AC unit's specifications and provide optimal airflow distribution.
Blower Wheels & Assemblies - Complete squirrel cage assemblies that work with blower motors to move air efficiently. These components must be properly balanced and sized for quiet operation and maximum airflow.
Technical Specifications:
Most RV blower motors operate on 12V DC power for furnaces or 115V AC power for air conditioning systems. Motors range from 1/20 HP to 1/4 HP depending on application, with specific RPM ratings to match system requirements. Many feature thermal overload protection to prevent damage from overheating.
Installation & Maintenance:
Blower motor replacement typically requires basic tools and can often be completed by RV owners with moderate technical skills. However, proper safety procedures must be followed, including disconnecting power and following manufacturer guidelines. Motors should be installed with correct rotation direction and proper electrical connections.
Regular maintenance includes cleaning blower wheels, checking for proper lubrication, and ensuring adequate ventilation around motor housings. Signs of motor failure include unusual noises, reduced airflow, overheating, or complete failure to operate.
Quality & Compatibility:
Our replacement motors meet or exceed OEM specifications for performance, reliability, and longevity. Each motor is matched to specific RV appliance model numbers to ensure proper fit and function. Many motors feature improved designs with better bearings, enhanced thermal protection, and quieter operation compared to original equipment.
Whether you're dealing with a failed furnace blower that's preventing heat distribution or an AC condenser fan that's causing your system to overheat, having the right replacement motor ensures your RV's climate control system operates efficiently and reliably for years of comfortable travels.