Genuine Atwood/Dometic replacement ignition control board for select gas-only Direct Spark Ignition RV water heaters.
The Atwood 91367 Ignition Control Circuit Board is the genuine OEM replacement control board for a wide range of Atwood gas-only Direct Spark Ignition RV water heaters. The control board manages the ignition sequence by receiving the call for heat and sending the electrical signal required to create spark and ignite the propane burner.
If your Atwood water heater has stopped igniting and diagnosis points to a failed control board, the 91367 allows you to replace the original electronic control without replacing the complete water heater. Because this is a genuine Atwood/Dometic replacement component, it is an excellent choice for RV owners who prefer to stay with the original equipment manufacturer.
Controls the electrical ignition sequence used to light the propane burner in compatible Atwood gas water heaters.
Integrated fuse provides additional protection for the control circuit against electrical faults.
Uses the spade-style electrode connection found on compatible Atwood water heater ignition systems.
Genuine Atwood/Dometic replacement board designed for proper fit and operation in supported applications.
The Atwood 91367 uses a spade-style electrode connection. Some older Atwood water heaters may use a different edge-style connector or require an adapter harness. Compare your existing board and connections before ordering. The replacement board may also be physically smaller than some older original boards. This does not necessarily indicate an incorrect part.
The Atwood 91367 is commonly used as a replacement for several earlier Atwood water heater control boards, including: • Atwood 91349 • Atwood 91420 • Atwood 91504 • Atwood 93254 • Atwood 93257 • Atwood 93307 • Atwood 93865 Always verify your original board number and water heater model before ordering.
Included: • Genuine Atwood/Dometic 91367 ignition control circuit board • Integrated fuse • Spade electrode connection Not Included: • Spark electrode • Water heater wiring harness • Edge-connector adapter, if required by an older installation
When your RV water heater calls for heat, the control board coordinates the gas ignition sequence. 1. Receives the call for water heating. 2. Controls the ignition sequence. 3. Sends power to the spark ignition circuit. 4. Allows the spark electrode to ignite the propane burner. 5. Monitors the ignition sequence so the water heater can operate properly.
A water heater that will not ignite does not automatically mean the control board has failed. Ignition problems can also be caused by a bad electrode, poor ground, damaged wiring, low 12V supply voltage, propane supply issues, thermostat/ECO problems, or other water heater components. Proper diagnosis is recommended before replacing the board.
The Atwood 91367 is used with many Atwood gas-only electronic ignition water heaters. Known compatible models include:
Model compatibility can vary by production date and wiring configuration. Confirm the water heater model and original control board number before ordering.
Locate the model number of your Atwood water heater and compare the part number and electrical connections on your existing control board. The 91367 is intended for compatible gas-only Direct Spark Ignition Atwood RV water heaters and uses a spade electrode connection.