Home > Home & Marine Upgrades > Blower Motors >

Dayton 1TDU9 Replacement Blower Motor 76 CFM 2680/3020 RPM 115V Ball Bearing (Replaces 4C940)

Dayton 1TDU9 replacement blower motor 76 CFM 115V ball bearing clockwise rotation direct replacement for Dayton 4C940 NBK 20534
Dayton Blower Motor, 76 CFM, 2680/3020 RPM, 115V
 
List Price: $126.00
: $69.49
You save $56.51!
Part Number: 1TDU9
Manufacturer: Dayton

Quantity in Stock :32

Availability: In Stock
Qty:

 
Dayton76 CFMClass B InsulationDayton 1TDU9 Replacement Blower Motor -- 76 CFM, 115V, Ball Bearing

The Dayton 1TDU9 is a direct-replacement blower motor engineered for dependable airflow in HVAC, furnace, and ventilation applications. With a compact housing, ball bearing construction, and automatic overload protection, it slots in where the original Dayton 4C940 lived -- no modifications required. Also cross-referenced as NBK Parts 20534.

Direct-Fit Blower Motor with Ball Bearing Durability

When your original blower motor wears out, a precise drop-in replacement saves time and eliminates guesswork. The 1TDU9 matches the housing dimensions, shaft diameter, rotation direction, and electrical specs of the Dayton 4C940 exactly, making it a reliable service replacement for furnaces, air handlers, small HVAC units, and similar blower-equipped equipment.

Ball bearing construction extends service life compared to sleeve bearing designs, especially in installations where the motor runs for extended periods or in higher-temperature environments. The 450 deg F maximum inlet temperature rating makes this motor suitable for demanding thermal environments.

76 CFM Airflow

Moves 76 cubic feet per minute at rated speed -- adequate for compact furnace and ventilation blower applications requiring consistent, steady airflow.

Dual-Speed Operation

Runs at 2680 RPM on 50 Hz or 3020 RPM on 60 Hz, making it compatible with both North American 60 Hz and international 50 Hz power systems.

Ball Bearing Construction

Ball bearings provide longer service life and handle higher operating temperatures better than sleeve bearings, reducing maintenance frequency.

Automatic Overload Protection

Built-in thermal overload protection shuts the motor down if it overheats, then automatically resets -- protecting the motor and the equipment it serves.

Direct Replacement for Dayton 4C940

The 1TDU9 is the listed replacement for Dayton model 4C940. Housing dimensions, shaft diameter (8mm), rotation direction (clockwise), and electrical characteristics are matched. Also cross-listed as NBK Parts number 20534.

Rotation and Orientation

This motor turns clockwise when viewed from the inlet side. Verify your application requires clockwise rotation before ordering -- installing a motor with the wrong rotation direction will reduce airflow efficiency significantly or push air the wrong direction through the housing.

50/60 Hz Dual-Frequency Rating

The motor is rated for both 50 Hz and 60 Hz operation at 115V. On 60 Hz (standard US), the wheel spins at 3020 RPM. On 50 Hz, it runs at 2680 RPM. Amps draw is 0.32A at 50 Hz and 0.30A at 60 Hz.

Wheel and Shaft Fitment Check

The shaft diameter is 8mm. If you are reusing the existing blower wheel from the Dayton 4C940, confirm the wheel bore is 8mm. If replacing the wheel at the same time, verify the 2-7/8 inch wheel diameter and 1-7/8 inch wheel width match your housing clearances. The inlet opening is 3-3/8 inches in diameter -- check your duct connection before installation.

Installation and Maintenance Tips
  • Disconnect power before removing the old motor. Confirm the circuit is de-energized with a meter.
  • Note wire color coding and terminal positions on the old motor before disconnecting leads.
  • Inspect the blower wheel for cracks or imbalance before reinstalling it on the new motor shaft.
  • After installation, run briefly and listen for bearing noise or vibration -- new ball bearings should run quietly from the start.
  • Clean the blower housing of any debris or buildup before reassembly to avoid recirculating particulate that can shorten bearing life.

Electrical Specifications

Voltage115V AC
Frequency50/60 Hz
Amperage0.32A (50 Hz) / 0.30A (60 Hz)
Insulation ClassClass B
Overload ProtectionAutomatic thermal reset

Performance Specifications

Airflow76 CFM
Speed (50 Hz)2680 RPM
Speed (60 Hz)3020 RPM
RotationClockwise (viewed from inlet)
Max Inlet Temperature450 deg F

Physical Dimensions

Overall Height5-7/8 in.
Overall Width6-1/8 in.
Overall Depth5-1/4 in.
Housing Height5-7/8 in.
Housing Width6-1/8 in.
Housing Depth5-1/4 in.
Weight6 lbs.

Wheel and Shaft Dimensions

Wheel Diameter2-7/8 in.
Wheel Width1-7/8 in.
Shaft Diameter8mm
Bearing TypeBall bearings

Inlet and Outlet Dimensions

Inlet Diameter3-3/8 in.
Outlet Height2-1/8 in.
Outlet Width2-5/8 in.
Flange Width3-5/16 in.
Flange Height3-1/2 in.

Part Number Cross-Reference

Dayton Part Number1TDU9
Replaces Dayton Model4C940
NBK Parts Number20534
Vendor/SKU20534
Important Information
  • Rotation is CLOCKWISE only -- confirm your application requires clockwise rotation before installation. A counter-clockwise application requires a different motor.
  • Shaft diameter is 8mm -- verify blower wheel bore before reuse. Standard SAE 5/16 in. bore wheels are NOT compatible without an adapter.
  • Rated 115V AC only. Do not connect to 230V circuits without an appropriate step-down transformer.
  • Max inlet air temperature is 450 deg F -- do not exceed this limit or motor insulation may be damaged.
  • Automatic overload protection will cycle the motor off if it overheats. If the motor repeatedly trips, investigate for airflow blockage, over-voltage, or mechanical binding before returning to service.
  • This listing is for the motor only. Blower wheel, housing, mounting hardware, and wiring connectors are not included unless explicitly stated.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Blower Motors
Home & Marine Upgrades


$14.49