Single-zone control panel for Furrion Chill rooftop air conditioners. Adjusts temperature (60-86°F), fan speed, and air distribution box functions. Short-cycle protection, auto restart, 2-speed auto fan, sleep mode, LED lighting. 115V AC/12V DC. R410A refrigerant systems only.
The Furrion FACC10SA-BL is the standard single-zone control panel for Furrion Chill rooftop RV air conditioners. It communicates with the system's thermostat to maintain a set temperature, and gives the user control over fan speed, air distribution box airflow, and other operating modes from inside the RV. It's compatible with all sizes of Furrion Chill rooftop units, and is one component of a complete AC setup that also includes the rooftop AC unit, thermostat, and air distribution box (ADB).
Short-cycle protection allows the AC unit to reach its temperature setpoint efficiently while protecting the compressor from rapid on/off cycling. Auto restart retains the controller's settings through a power failure — when power returns, the air conditioner resumes its last settings automatically. The 2-speed auto fan mode intelligently selects fan speed based on room temperature, and additional comfort features include sleep mode, LED mood lighting, and a memory function. The unit runs on 115V AC/12V DC and sets a temperature range of 60-86°F. Covered by Furrion's 24-month warranty.
• 1x FACC10SA-BL controller To complete a Furrion Chill AC setup, also required: • Furrion Chill rooftop AC unit • Single-zone thermostat • Air distribution box (ADB)
This controller is designed for air conditioning equipment using R410A refrigerant. Per Furrion: R410A-designed equipment cannot be used in R32-designed systems, and R32 refrigerant cannot be used in R410A-based air conditioners. Confirm your AC unit's refrigerant type before ordering — check the equipment label or documentation.
• FACC10SA-BL (this item): Standard single-zone controller, 2-speed • FACC10ESSA-BL: Enhanced standard single-zone controller, 2-speed, with additional features Both share the same Furrion Single Zone Controller Quick Start Guide. Confirm which version matches your existing system before replacing — the Enhanced version may include features not present on the standard controller.