Lippert Girard 2022107592 2GWH-32 Blower Motor Assembly replacement part for RV tankless water heaters
Girard Blower Motor Assembly for RV Tankless Water Heaters
 
List Price: $199.89
: $173.99
You save $25.90!
Part Number: 2022107592
Manufacturer: Lippert

Quantity in Stock :30

Free Shipping
Availability: In Stock
Qty:

 
Lippert / Girard OEM Replacement Part 2GWH-32 Series Girard 2GWH-32 Blower Motor Assembly -- Part 2022107592

When your Girard tankless water heater stops igniting or loses consistent hot water output, a failed blower motor is often the cause. This genuine OEM assembly restores proper combustion airflow so your 2GWH-32 unit runs reliably again -- no fabrication, no adapting, no guesswork.

OEM Blower Motor for Girard 2GWH-32 RV Tankless Water Heaters

The Girard 2022107592 is a genuine factory replacement blower motor assembly engineered specifically for the 2GWH-32 on-demand tankless water heater. The blower motor is a critical component in the combustion system -- it draws in fresh air, maintains the proper air-to-fuel ratio, and ensures the burner fires safely and consistently. When the motor wears out or fails, the unit typically shuts down on a fault code or simply will not ignite.

Because this is an OEM assembly sourced through Lippert (who acquired Girard), it matches the original mounting configuration, connector pinout, and motor speed profile of the factory unit. Direct-swap installation means no wiring modifications and no bracket fabrication.

OEM Exact Match

Same mounting pattern, connector, and motor spec as the factory blower -- direct swap, no modification needed.

Combustion Airflow

Maintains correct air-to-fuel ratio for safe, reliable ignition on every call for hot water.

Genuine Lippert / Girard

Factory part backed by Lippert -- the current manufacturer and warranty service provider for Girard water heaters.

2GWH-32 Series Specific

Designed for the 2GWH-32 model only. Verify your model number before ordering.

Why Replace the Blower Motor?

  • Unit displays a fault code and will not ignite -- common symptom of blower failure
  • Blower runs but water heater does not produce consistent heat
  • Motor is noisy, rattling, or noticeably slower than normal
  • Blower does not spin at startup even though the unit receives power
  • Replacing the blower motor is typically more cost-effective than replacing the full water heater assembly

About the Girard 2GWH-32

The 2GWH-32 is a propane-fired, on-demand tankless water heater designed for RV use. It produces hot water only when called for, with no standing pilot and no tank to keep heated. The combustion blower is integral to its sealed-combustion design, drawing outside air for the burner and exhausting combustion gases -- making the blower motor one of the highest-wear components in the system.

Installation Tips

  • Turn off LP gas supply and disconnect 12V power before disassembly
  • Photograph all wiring connections before removing the old motor -- connector orientation matters
  • Inspect the blower housing and impeller for debris or corrosion while the unit is open
  • After reassembly, test for ignition and verify no LP smell at all connection points
  • A propane leak test with soapy water or a detector is recommended after any gas-appliance service

Also Consider When Servicing Your 2GWH-32

While the water heater is open for blower motor service, it is a good time to inspect the igniter electrode, flame sensor, and LP inlet valve. Addressing related wear items in a single service visit saves time and reduces repeat disassembly.

Part Identification

ManufacturerLippert (Girard)
Part Number (OEM)2022107592
Vendor Part Number11-9162
UPC846611001018
ComponentBlower Motor Assembly
Series2GWH-32

Compatibility

Fits ModelGirard 2GWH-32 RV Tankless Water Heater
ApplicationRV / motorhome propane tankless water heater
ReplacesOEM factory blower motor in 2GWH-32 units
Not Compatible With2GWH-D, 2GWH-2, or other non-32 Girard models -- verify model before ordering

Electrical

System Voltage12V DC (standard RV house power)
FunctionCombustion air supply and exhaust for sealed-combustion burner

What Is Included

In the BoxBlower motor assembly (1 unit)
Not IncludedMounting hardware, wiring harness, igniter, flame sensor, or other water heater components

Regulatory / Certification

Part TypeGenuine OEM replacement -- not aftermarket
Current DistributorLippert Components (acquired Girard product line)

Important Information

  • Verify your model number first. This blower motor assembly fits the 2GWH-32 only. Installing an incorrect blower in a propane appliance is a safety hazard.
  • Propane appliance service. Always shut off LP gas at the source and disconnect 12V power before beginning any disassembly. Work in a well-ventilated area.
  • Leak test required. After reinstallation, test all LP fittings before relighting. Do not operate the water heater if any gas smell is detected.
  • Not a complete water heater kit. This is a single replacement component. Additional hardware, wiring, or related parts are not included.
  • OEM part -- limited substitution. Do not substitute aftermarket blower motors in sealed-combustion RV appliances unless the replacement is rated and approved for the specific application.


Browse for more RV Accessories in the same category as this item:

Appliances > RV Water Heater Parts