Home > Fresh Water > Hose Fittings & Regulators >

Camco 40395 Vacuum Breaker Assembly 1/2" NPT Male x Male 125 PSI Backflow Prevention for RV Fresh Water

Camco 40395 Vacuum Breaker Assembly with 1/2-inch NPT male threads and 125 PSI rating for RV fresh water backflow prevention
Camco Vacuum Breaker Assembly, 1/2" NPT, 125 PSI, Backflow Prevention for RV Fresh Water
 
Alternative Views:


List Price: $16.99
: $12.99
You save $4.00!
Part Number: 40395
Manufacturer: Camco

Quantity in Stock :38

Availability: In Stock
Qty:

 
Camco 1/2" NPT 125 PSI Rated Camco 40395 Vacuum Breaker Assembly -- RV Fresh Water Backflow Prevention

A fast, code-compliant solution that installs between any standard campground water spigot and your RV fresh water hose in seconds -- protecting your potable water supply from back-siphonage contamination every time you hook up.

Stop Contamination Before It Starts

Campground water spigots serve dozens of rigs. Without a vacuum breaker installed, a sudden drop in city water pressure can create a siphon that pulls water -- and anything it has contacted -- backward from your RV hose into the municipal supply. The Camco 40395 breaks that siphon the instant pressure drops, keeping your fresh water system safe and the campground supply uncontaminated.

Installation takes under a minute: thread the 40395 directly onto the spigot, then attach your RV fresh water hose to the other end. No tools, no adapters, no separate check valve needed. Many campgrounds and state parks require a backflow prevention device by rule -- this assembly satisfies that requirement.

Instant Siphon Protection

Atmospheric vent opens automatically when supply pressure drops, stopping back-siphonage before contamination can occur.

1/2" NPT Both Ends

Male NPT threads on inlet and outlet match standard campground spigots and RV hose fittings -- no adapters required in typical setups.

125 PSI Rated

Handles well above typical campground water pressure (40-80 PSI), with headroom for high-pressure sites up to 125 PSI working pressure.

Compact Thermoplastic Body

Lightweight polymer construction resists corrosion. Small enough to leave attached to your hose between hookups.

Why Every RV Setup Needs a Vacuum Breaker

A pressure regulator limits the PSI coming into your RV but does nothing to prevent back-siphonage. A water filter keeps particulates out but cannot stop reverse flow. A vacuum breaker is the only device specifically designed to break the siphon created by a pressure drop at the source -- it is a separate, non-redundant safeguard in your water connection chain.

The correct hookup order at the spigot is: spigot -- vacuum breaker (40395) -- pressure regulator -- water filter -- RV inlet hose. Placing the vacuum breaker first, directly at the spigot, gives it the widest protection window.

Campground Compliance

Many state and private campgrounds, as well as local health codes, require a backflow prevention device on any RV water connection. The Camco 40395 satisfies this requirement and fits all standard 1/2" garden-hose-to-NPT spigot configurations common at full-hookup sites.

Where It Fits in Your Water Chain

  • Install directly on the campground spigot (outlet) -- first device in line
  • Thread your RV fresh water hose onto the outlet end of the 40395
  • Add a pressure regulator (such as Camco 40055 or 40064) downstream of the vacuum breaker
  • Add an inline water filter (such as Camco TastePURE) downstream of the regulator
  • Connect filtered, regulated, protected water to your RV city water inlet

Not a Pressure Regulator

The Camco 40395 prevents back-siphonage only -- it does not reduce or regulate incoming water pressure. Always use a separate RV pressure regulator to protect your RV plumbing from high campground PSI. Typical RV plumbing is rated for 45-60 PSI; campground supplies can exceed 100 PSI.

Maintenance Tips

  • Inspect the vent port on the side of the body after each season -- mineral deposits can clog the atmospheric vent and reduce effectiveness
  • Flush with clean water after use in areas with high sediment or hard water
  • Store indoors during freezing temperatures -- standing water in the body can crack the thermoplastic housing
  • Replace if the vent port is visibly cracked or if the body shows thread damage

Specifications

Manufacturer Part Number40395
Vendor Part Number23-0328
UPC014717403955
BrandCamco

Thread and Connection

Inlet Thread1/2" NPT male
Outlet Thread1/2" NPT male
Thread StandardNPT (National Pipe Thread Taper)
Compatible Hose FittingsStandard 3/4" GHT RV fresh water hose with 1/2" NPT female coupling

Ratings and Materials

Maximum Working Pressure125 PSI
Body MaterialThermoplastic polymer
Device TypeAtmospheric vacuum breaker (AVB)
Flow DirectionOne-way (inlet to outlet); vent opens on pressure loss

Application

Primary UseRV fresh water hookup -- campground spigot to RV hose
Protection TypeBack-siphonage prevention (not back-pressure backflow)
Typical Install LocationFirst device on campground spigot outlet
Compatible SystemsAll standard RV city water inlet systems; potable fresh water use

In the Box

Included1x Camco 40395 vacuum breaker assembly
Not IncludedPressure regulator, water filter, fresh water hose, thread seal tape

Important Information

  • This device prevents back-siphonage only -- it is not a backpressure backflow preventer. Do not use as the sole protection against backpressure situations.
  • Always use a separate RV pressure regulator to prevent over-pressure damage to RV plumbing. The 40395 does not regulate or reduce incoming PSI.
  • Do not install with the vent port facing downward -- the atmospheric vent must be able to open freely to function correctly.
  • Not rated for continuous hot water service. Use on cold potable water lines only.
  • Apply thread seal tape (PTFE) to NPT connections to ensure a watertight seal and prevent galling on thermoplastic threads.
  • Inspect for freeze damage before each season. A cracked body will not maintain a safe seal.


Browse for more RV Accessories in the same category as this item:

Fresh Water > Hose Fittings & Regulators
Fresh Water