Home > Fresh Water > RV Water Pump Parts & Fittings >

Remco Industries 901-009-R Sprayer Pump Wire Harness Kit 90 Inch 16 AWG 30 Amp with SAE Connectors

Remco Industries 901-009-R 90-inch sprayer pump wire harness kit with 16 AWG wire, 30 amp on/off switch, and 2-pin SAE connectors
Remco Sprayer Pump Wire Harness Kit, 90"
 
: $29.98
Part Number: 901-009-R
Manufacturer: Remco Industries

Quantity in Stock :4

Availability: In Stock
Qty:

 
Remco Industries 16 AWG -- 30 Amp Part No. 901-009-R Remco 901-009-R Sprayer Pump Wire Harness Kit -- 90 Inch

A purpose-built wiring solution for 12-volt sprayer pumps, the Remco 901-009-R gives you 90 inches of heavy-duty 16 AWG bonded copper wire, a 30 amp on/off switch, standard 2-pin SAE connectors on both ends, and two 12-inch extension leads so you can power your pump from a battery or a 12V vehicle outlet -- no improvised splicing, no undersized wire.

Professional-Grade Wiring for 12V Sprayer Pumps

Undersized wire and flimsy switches are the leading cause of sprayer pump failures in the field. The Remco 901-009-R eliminates that risk by pairing heavily insulated 16 AWG bonded copper conductors with a 30 amp rated on/off switch -- well above the draw of even high-output 5.3 GPM sprayer pumps. The result is stable voltage delivery, minimal heat buildup, and a switch that holds up to repeated cycling in wet, dusty, and vibration-prone environments.

Both ends of the 90-inch main harness terminate in the standard 2-pin SAE connector used across Remco's 2200, 2400, 3200, 3300, and 5500 Series pumps as well as many competing brands. The kit also includes two 12-inch extension leads -- one with 30 amp battery clips for direct battery connections and one with a 12-volt car adapter plug for cab or accessory outlet hookups.

16 AWG Bonded Copper Wire

Red and black bonded pair with heavy insulation. Handles up to 30 amps continuously for low-resistance power delivery across the full 90-inch run.

30 Amp On/Off Switch

Heavy-duty switch rated for repeated cycling. Controls pump power without interrupting the circuit at the battery -- no need to disconnect leads to stop the pump.

Standard 2-Pin SAE Connectors

Both ends use the industry-standard 2-pin SAE plug compatible with Remco pumps and most other 12V sprayer pump brands. Plug-and-play installation, no crimping required.

Dual 12" Extension Leads

Includes one 12-inch lead with 30 amp battery clamps and one 12-inch lead with a 12V car adapter. Power from a dedicated battery bank or a vehicle accessory outlet.

Compatible Pump Applications

This harness is engineered for 12-volt demand sprayer pumps operating between 1.0 GPM and 5.3 GPM. Confirmed compatible pump families include:

  • Remco 2200 Series -- 12V sprayer pumps
  • Remco 2400 Series -- 12V sprayer pumps
  • Remco 3200 Series -- 12V sprayer pumps
  • Remco 3300 Series -- 12V sprayer pumps
  • Remco 5500 Series -- 12V sprayer pumps up to 5.3 GPM
  • Any third-party 12V sprayer pump using a standard 2-pin SAE connector
Direct Plug-In Convenience: The 2-pin SAE connector is the industry standard for 12V sprayer pumps. If your pump already has this connector, the 901-009-R installs without any additional adapters or terminal work.

Typical Installation Setup

The 90-inch main harness bridges the distance between your power source and the pump mounting location -- enough reach for most ATV, UTV, skid sprayer, and pickup bed installations. Route the harness away from sharp edges and heat sources, secure with zip ties, and connect the appropriate 12-inch extension to your power source.

  • Battery-powered setup: Use the 30 amp battery clip extension attached directly to a 12V battery or terminal block.
  • Vehicle outlet setup: Use the 12V car adapter extension plugged into a cab or accessory port rated for at least 15 amps.
  • Always confirm the vehicle's accessory fuse is rated appropriately for the pump's amp draw before using the car adapter extension.
Wire Sizing Note: 16 AWG wire at 90 inches (7.5 feet) is appropriate for sprayer pumps drawing up to approximately 15 amps continuous. The 30 amp switch provides headroom for startup surge current. For sustained high-draw applications near 5.3 GPM, verify your pump's actual amp draw against this wire gauge for your specific installation length.
Maintenance Tip: Periodically inspect SAE connector contacts for corrosion, especially in agricultural spraying environments where chemical residue or moisture can accumulate. A light application of dielectric grease to the connector pins extends contact life significantly.

Electrical Specifications

Part Number901-009-R
UPC816624018341
Wire Gauge16 AWG
Wire TypeRed and black bonded copper, heavily insulated
Switch Rating30 amps
Switch TypeHeavy-duty on/off toggle
System Voltage12V DC

Physical Specifications

Main Harness Length90 inches (7.5 feet)
Extension Lead Length12 inches each (x2 leads included)
Connector Type2-pin SAE (standard sprayer pump connector)
Weight0.1 lb.

Package Contents

Item 11x wire harness, 90" length with on/off switch and 2-pin SAE connectors on each end
Item 21x 12" extension with 30 amp battery clips
Item 31x 12" extension with 12-volt car adapter plug

Compatibility

Pump Voltage12V DC only
Pump Flow Range1.0 GPM to 5.3 GPM
Remco Series Fit2200, 2400, 3200, 3300, 5500 Series
Connector Standard2-pin SAE (fits most 12V sprayer pump brands)

Manufacturer

BrandRemco Industries
Product LineSprayer Pump Accessories
Country of UseNorth America
Important Information
  • This harness is rated for 12V DC systems only. Do not use with 24V systems.
  • The 16 AWG wire is designed for sprayer pump applications up to 5.3 GPM. Do not exceed the 30 amp switch rating or use this harness on pumps with higher current draw.
  • When using the 12V car adapter extension, confirm the vehicle outlet and its fuse can supply adequate current for the pump being used. Many factory accessory outlets are fused at 10-15 amps.
  • Route wire away from moving parts, sharp edges, exhaust components, and chemical contact points.
  • This kit does not include a pump. Sprayer pump sold separately.
  • Do not operate the pump dry. The wire harness powers the pump but does not protect against dry-run damage to pump internals.


Browse for more RV Accessories in the same category as this item:

Fresh Water > RV Water Pump Parts & Fittings
Fresh Water
Fresh Water > Remco Water Pumps > Remco Pump Parts & Accessories
Fresh Water > Remco Water Pumps