Home > Electrical > Generator Parts & Accessories >

Cummins Onan 308-1038 Control Panel Rocker Switch for RV QG 2500 & QG 4000 Spec J+ Generators

Cummins Onan 308-1038 Control Panel Rocker Switch for RV QG 2500 & QG 4000 Spec J+ Generators
Cummins Onan Control Panel Rocker Switch for RV QG 2500 & QG 4000 Spec J+ Generators
 
List Price: $82.99
: $66.49
You save $16.50!
Part Number: 308-1038
Manufacturer: Cummins Onan

Quantity in Stock :14

Availability: In Stock
Qty:

 
Cummins Onan 308-1038 Control Panel Rocker Switch for RV QG 2500 & QG 4000 Spec J+ Generators

Cummins Onan 308-1038 Control Panel Rocker Switch for RV QG 2500 & QG 4000 Spec J+ Generators

Genuine Onan generator-mounted start/stop rocker switch for select RV QG, KY, and HGJ series generator control panels.

Why Replace the Generator Rocker Switch?

The Cummins Onan 308-1038 is a replacement rocker switch used at the generator control panel on select Onan RV generator models. If the original start/stop switch is cracked, worn, sticking, intermittent, or no longer responding properly, replacing the switch can help restore normal local generator control.

This switch is commonly listed for Onan RV QG 2500 and RV QG 4000 Spec J and newer applications, as well as select KY and HGJ series generators. This is the rocker switch on the generator itself, not the remote interior start/stop panel.

🔘 Start/Stop Switch

Replacement rocker switch for generator-mounted start and stop control

🔧 Genuine Onan Part

Designed for compatible Onan RV generator control panel applications

🏕️ RV Generator Use

Commonly listed for select RV QG, KY, and HGJ generator models

⚠️ Not Remote Panel

This is the switch on the generator, not the interior remote panel assembly

⚠️ Important Fitment Note

This rocker switch is not universal for every Onan generator. Cummins lists it for RV QG 2500 / 2.5HGJBB and RV QG 4000 Spec J and newer models, while other RV parts references list it for Onan KY Spec J and newer plus select HGJAA, HGJAB, and HGJAC applications.

Before ordering, verify your generator model, spec letter, and existing switch style. This part is for the generator-mounted control panel switch and does not replace an interior remote panel, remote harness, or generator control board.

Key Features & Benefits

  • Generator-Mounted Rocker Switch: Replaces the local start/stop switch on compatible Onan generator control panels
  • Genuine Cummins Onan Replacement: Built for compatible Onan RV generator applications
  • Listed Fits: Cummins lists fitment for RV QG 2500 / 2.5HGJBB and RV QG 4000 Spec J and up
  • KY and HGJ References: Also commonly listed for Onan KY Spec J and later plus select HGJAA, HGJAB, and HGJAC generators
  • Useful Repair Part: Helps address a damaged, worn, loose, or non-responsive generator start/stop switch
  • Control Panel Component: Intended for the generator control panel, not the RV interior remote switch panel
  • Model Verification Recommended: Confirm generator model and spec letter before ordering
  • Switch Only: Does not include remote panel, wiring harness, fuse, control board, or generator service parts

Product Specifications

Part Number308-1038
Alternate Format0308-1038
BrandCummins Onan
Component TypeGenerator Control Panel Rocker Switch
Switch FunctionStart / Stop
Installation LocationGenerator-Mounted Control Panel
Common Cummins Listed FitsRV QG 2500 / 2.5HGJBB, RV QG 4000 Spec J and Up
Additional Common ReferencesOnan KY Spec J and Later, HGJAA, HGJAB, HGJAC
Warranty12-Month Cummins Parts / Accessories Warranty
Universal FitNo — Verify Generator Model and Spec Letter

📋 Installation Overview

Before Starting: Turn off the generator, allow it to cool, and follow all RV/generator electrical safety precautions before servicing the control panel.

Basic Replacement Steps:

1. Confirm Compatibility: Verify generator model, spec letter, and existing switch style before removing parts.

2. Disconnect Power: Disconnect generator starting power as required by the service procedure.

3. Access Control Panel: Remove the necessary generator control panel cover or access panel.

4. Document Wiring: Take a photo of the existing switch wiring before disconnecting terminals.

5. Remove Old Switch: Carefully release the old rocker switch from the panel opening.

6. Install New Switch: Connect the wiring to the replacement switch in the same arrangement and seat the switch in the panel.

7. Test Operation: Restore power and confirm that the generator starts and stops properly from the local switch.

📦 What's Included

Package Contents:
• Cummins Onan 308-1038 rocker switch

NOT Included — May Also Need:
• Interior remote panel
• Remote wiring harness
• Fuse or fuse holder
• Generator control board
• Control panel cover or trim
• Additional wiring terminals or connectors

This listing is for the rocker switch only. Reuse existing serviceable wiring and hardware unless replacement parts are required.

📄 Cummins Onan Generator Support

To confirm compatibility before ordering, have the following ready:
• Generator model number
• Spec letter
• Serial number
• Existing switch part number, if visible
• Whether the switch is on the generator or inside the RV

Why this matters: Onan generator switches and remote panels can look similar in function but are not always interchangeable. Matching the generator model/spec and switch location helps avoid ordering the wrong control part.

Rocker Switch Fitment Check

Fitment Point 308-1038 Reference What to Verify
Switch Location
Generator-mounted control panel
Confirm you are replacing the switch on the generator, not an interior remote panel
Cummins Listed Fits
RV QG 2500 / 2.5HGJBB and RV QG 4000 Spec J and up
Check model and spec letter on the generator nameplate
Additional References
KY Spec J and later, HGJAA, HGJAB, HGJAC
Confirm exact KY or HGJ model/spec before ordering
Function
Start / stop rocker switch
Verify the issue is with the switch and not wiring, fuse, battery, or control board
Harness
Not included
Inspect existing wiring and terminals for corrosion, looseness, or damage
Remote Control
Not a remote panel replacement
Use a remote panel part number if replacing the RV interior switch assembly

Match this switch by generator model/spec and switch location. The 308-1038 is for the generator-mounted rocker switch, not the interior remote start/stop panel.

Start/Stop Switch Troubleshooting — Switch vs. Other Causes

Symptom Possible Switch Issue Other Possible Causes to Check
Generator will not start from local switch
Worn, damaged, or failed rocker switch
Battery issue, fuse, wiring, generator control board, fuel supply, or generator fault
Switch feels loose or sticks
Mechanical switch wear or broken rocker housing
Panel damage, debris around switch opening, or loose mounting fit
Generator starts remotely but not locally
Generator-mounted switch or local switch wiring may be faulty
Loose terminal, damaged control panel wiring, or generator control circuit issue
Generator starts locally but not remotely
Local rocker switch may be working normally
Interior remote panel, remote harness, connectors, or remote wiring circuit
Intermittent start/stop response
Internal switch contacts may be worn or inconsistent
Loose wiring terminals, low battery voltage, corroded connector, or vibration-related wiring fault

If the generator does not respond from the local switch, inspect the switch, wiring terminals, fuses, battery voltage, and generator-side control circuit before replacing parts.



Browse for more RV Accessories in the same category as this item:

Electrical > Generator Parts & Accessories
Electrical


$35.99