Home > Home & Marine Upgrades > Blower Motors >

Dayton 1TDP8 Replacement Blower Motor 184 CFM 2750/3150 RPM 115V -- Replaces 4C015

Dayton 1TDP8 replacement blower motor 184 CFM 115V dual-speed ball bearing motor replaces Dayton 4C015 NBK 20498
Dayton Blower Motor, 184 CFM, 2750/3150 RPM, 115V
 
List Price: $150.59
: $82.99
You save $67.60!
Part Number: 1TDP8
Manufacturer: Dayton

Quantity in Stock :34

Availability: In Stock
Qty:

 
Dayton184 CFMClass B InsulationDayton 1TDP8 Blower Motor -- 184 CFM, 2750/3150 RPM, 115V

A direct-replacement blower motor engineered to restore airflow in furnaces, ventilation units, and HVAC equipment. The 1TDP8 steps in where the original Dayton 4C015 left off -- same electrical specs, same compact footprint, ball-bearing construction for long service life, and automatic overload protection to guard the motor against thermal runaway.

Drop-In Replacement for the Dayton 4C015 Blower Motor

The Dayton 1TDP8 is a factory-spec replacement blower motor designed to swap directly into applications previously served by Dayton model 4C015. It is also sold under the NBK Parts number 20498. If your furnace, air handler, or ventilation blower is running slow, overheating, or has stopped turning, this motor restores full airflow without custom fabrication or wiring changes.

At 184 CFM through a 2-5/8 in inlet, the 1TDP8 moves a meaningful volume of air for its compact 8-3/8 in x 5-3/8 in x 5-3/4 in envelope. The dual-speed design (2750 RPM at 60 Hz, 3150 RPM at 50 Hz) means it operates correctly on both North American 60 Hz and international 50 Hz power systems -- useful for imported equipment or specialized applications.

Ball Bearing Construction

Precision ball bearings replace the sleeve bearings found in lower-cost motors. Ball bearings handle higher temperatures, last longer under continuous duty, and tolerate both horizontal and vertical shaft orientations.

Automatic Overload Protection

An integrated thermal overload protector cuts power if the motor overheats and automatically resets once it cools. This protects both the motor and surrounding equipment from damage caused by blocked airflow or stalled conditions.

Dual-Frequency Operation

Rated for both 50 Hz and 60 Hz service. Speed adjusts accordingly -- 3150 RPM at 50 Hz, 2750 RPM at 60 Hz -- so the motor works correctly across different power environments without rewiring.

Compact, Precise Dimensions

Overall envelope of 8-3/8 in wide x 5-3/8 in deep x 5-3/4 in tall with a 4-1/16 in x 3-9/16 in flange and an 8 mm shaft diameter. Designed to fit the same mounting cutout as the 4C015 it replaces.

Direct Replacement: The 1TDP8 replaces Dayton model 4C015 with no modifications required. The flange dimensions, shaft diameter, and electrical specs are matched to the original motor. Also cataloged as NBK Parts 20498 for cross-reference purposes.
Rotation: This motor supports both clockwise and counter-clockwise rotation. Verify your application's required rotation direction before installation. Many blower wheels are directional -- running the wheel in the wrong direction significantly reduces airflow and can damage the housing.
Max Inlet Temperature: Do not exceed 104 deg F (40 deg C) at the motor inlet. Operating above this limit will degrade insulation life and may void the thermal overload protection's effectiveness. Ensure adequate clearance and airflow around the motor body during installation.
Maintenance Tips:
  • Ball-bearing motors generally do not require lubrication, but inspect the shaft and wheel hub for debris annually.
  • Check the blower wheel set screw torque after initial run-in -- the 8 mm shaft can allow slight wheel migration if the screw was not fully seated.
  • If the motor trips its thermal overload repeatedly, investigate the root cause (blocked duct, failed capacitor, low voltage) before assuming the motor is faulty.

Electrical Specifications

Voltage115V AC
Frequency50/60 Hz
Amperage (60 Hz)0.74 A
Amperage (50 Hz)0.72 A
Speed (60 Hz)2750 RPM
Speed (50 Hz)3150 RPM
Insulation ClassClass B
Overload ProtectionAutomatic thermal reset

Airflow Specifications

Airflow184 CFM
Inlet Diameter2-5/8 in
Outlet Height2-1/8 in
Outlet Width2-5/8 in
Max Inlet Temperature104 deg F (40 deg C)

Physical Dimensions

Overall Width8-3/8 in
Overall Depth5-3/8 in
Overall Height5-3/4 in
Flange Size4-1/16 in W x 3-9/16 in H
Shaft Diameter8 mm
Wheel Diameter2-7/8 in
Wheel Width1-7/8 in
Weight6 lbs

Bearing and Construction

Bearing TypeBall bearings
RotationClockwise / counter-clockwise
MountingFlange mount

Identification and Cross-Reference

Dayton Part Number1TDP8
ReplacesDayton 4C015
NBK Parts Number20498
ManufacturerDayton
Important Information
  • Maximum inlet air temperature is 104 deg F. Exceeding this rating shortens insulation life and risks motor failure.
  • Verify rotation direction required by your blower wheel before installation -- incorrect rotation drastically reduces airflow efficiency.
  • This motor operates on 115V AC only. Do not connect to 230V circuits without a step-down transformer.
  • The thermal overload protector resets automatically after cooling. Repeated tripping indicates an underlying problem that must be corrected, not ignored.
  • Confirm the replacement model (4C015) against your equipment's nameplate before ordering. Blower motors with similar CFM ratings are not always dimensionally interchangeable.
  • Blower wheel and mounting hardware are not included. Reuse the existing wheel only if it is in good condition and properly balanced.