Home > Home & Marine Upgrades > Blower Motors >

Fasco A150 Draft Inducer Blower Motor for Fasco/Trane Furnaces -- 208-230V, 3000 RPM, 3.3" Dia, SKU 12178

Fasco A150 draft inducer blower motor 208-230V 3000 RPM 3.3-inch diameter replacement for Trane and Fasco furnaces SKU 12178
Fasco Furnace Draft Inducer Blower Motor For Fasco/Trane, 208-230V, 3000 RPM
 
List Price: $211.77
: $116.99
You save $94.78!
Part Number: A150
Manufacturer: Fasco

Quantity in Stock :37

Free Shipping
Availability: In Stock
Qty:

 
Fasco 208-230V / 3000 RPM UL & CSA Listed Fasco A150 Replacement Draft Inducer Blower Motor for Fasco and Trane Furnaces

A direct-replacement draft inducer blower motor built to match the original Fasco A150 specification. Designed for residential and light-commercial furnaces from Fasco and Trane, this shaded-pole motor delivers reliable combustion airflow with ball-bearing construction and built-in thermal overload protection. Also cataloged as NBK Parts 12178 and Packard 82253.

Reliable Draft Inducer Replacement -- Matched to OEM Specs

The draft inducer motor is one of the most cycle-intensive components in a forced-air furnace. It must spin up reliably on every call for heat, maintain consistent airflow through the heat exchanger, and survive thousands of on/off cycles over its service life. When the original Fasco or Trane inducer motor fails -- shown by a humming but non-spinning wheel, a furnace that locks out on pressure-switch fault, or an audibly grinding bearing -- this A150 motor restores full function without modification.

This motor ships with 24-inch stripped leads ready for direct connection to the OEM wire harness. No adapter harness or bracket fabrication is required for the compatible models listed below.

Ball Bearing Construction

Ball bearings -- not sleeve bearings -- handle the heat and vertical shaft loads common in inducer applications, providing longer service life in high-cycle furnace environments.

Built-In Thermal Protection

Integrated thermal overload protector shuts the motor down before winding damage occurs if airflow is restricted or ambient temps exceed the rated 104 deg F / 40 deg C limit.

UL and CSA Listed

Meets UL and CSA safety standards required for furnace blower motor replacements in the US and Canada. Suitable for permitted HVAC service work.

Class B Insulation

Class B winding insulation is rated to 266 deg F (130 deg C), providing a meaningful thermal margin above the motor's operating range in typical furnace applications.

Compatible Models -- Direct Replacement Cross-Reference

This motor is a verified replacement for the following OEM and aftermarket part numbers. If your existing motor carries any of these numbers on its label, the Fasco A150 / NBK 12178 is the correct replacement.

  • Fasco A150 (primary OEM number)
  • Fasco 7021-10286
  • Fasco 7021-7833
  • Fasco 7021-8928
  • Trane 21C729631P1
  • Trane 4MH39
  • Trane 7021-10286
  • Trane 7021-7833
  • Trane 7021-8928
  • Trane BLW-451 / BLW00451
  • Trane C661452P01
  • Trane X38080029010
  • Packard 82253
  • Universal U9447
  • W.W. Grainger 4MH39
  • NBK Parts 12178
Verify Before Ordering: Confirm the part number on the motor label of the unit being replaced matches one of the cross-references above. Also confirm your supply voltage is 208-230V single-phase, 60 Hz before installation.

What Comes in the Box

  • One (1) Fasco A150 draft inducer blower motor
  • 24-inch leads, pre-stripped for termination
Note: This listing is for the motor only. The blower wheel, housing, mounting bracket, and pressure switch are NOT included. Reuse the existing wheel and housing from the original assembly, or order those components separately if they are damaged.

Typical Failure Symptoms This Motor Resolves

If your furnace exhibits any of the following, the draft inducer motor is a common cause:

  • Furnace locks out on a "pressure switch open" fault code at startup
  • Inducer assembly hums but the blower wheel does not spin (seized bearing or open winding)
  • Audible grinding, squealing, or rattling from the inducer housing during the pre-purge cycle
  • Motor runs but intermittently trips the thermal protector due to failing bearings creating excess heat
Installation Note: Mark the blower wheel's orientation on the shaft before removal. Reinstall to the same depth and set-screw position to maintain proper wheel-to-housing clearance. Torque the set screw to the wheel manufacturer's specification -- typically 10-12 in-lb for standard inducer wheels.
Maintenance Tip: While the inducer is disassembled, inspect the condensate drain port on the housing for blockage, and check the rubber gasket between the motor housing and the furnace vestibule for cracking. A cracked gasket allows combustion gases to bypass the heat exchanger and should be replaced at the same service visit.

Electrical Specifications

Voltage208-230V AC
Frequency60 Hz
PhaseSingle phase
Motor TypeShaded pole
Full Load Current0.16 amps
Speed3000 RPM
Insulation ClassClass B (130 deg C / 266 deg F)
Thermal ProtectionBuilt-in automatic reset

Physical Specifications

Frame Diameter3.3 inches
Bearing TypeBall bearings
Lead Length24 inches, stripped ends
Weight5 lbs
Ambient Temp Rating104 deg F (40 deg C) maximum

Certifications and Listings

UL ListedYes
CSA ListedYes

Part Number Cross-Reference

Fasco OEMA150
NBK / SKU12178
Packard82253
UniversalU9447
Grainger4MH39
Trane (primary)BLW00451 / BLW-451

Application Summary

Primary ApplicationFurnace draft inducer blower
Compatible BrandsFasco, Trane
Voltage Requirement208-230V single-phase, 60 Hz
Motor OnlyYes -- blower wheel and housing not included
Important Information
  • This motor is rated for 208-230V, 60 Hz, single-phase power only. Do not connect to 120V circuits or 50 Hz supplies.
  • The blower wheel, housing, mounting bracket, and gaskets are NOT included. Reuse or separately source those components.
  • Disconnect and lock out power to the furnace before beginning any motor replacement work.
  • Maximum ambient operating temperature is 104 deg F (40 deg C). Do not install in locations that exceed this rating.
  • Confirm the part number on the original motor label matches a listed cross-reference before installation. Incorrect RPM or rotation direction will cause pressure-switch faults and furnace lockout.
  • UL and CSA listings apply to the motor assembly only. Installation must comply with all applicable local codes and the furnace manufacturer's service documentation.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Blower Motors
Home & Marine Upgrades