Home > Appliances > Air Conditioners >

GE Profile PLHS13XAHB Low Profile RV Rooftop Air Conditioner with Heat Pump, 13,500 BTU, R-32, Black

GE Profile PLHS13XAHB low-profile RV rooftop air conditioner with heat pump, 13,500 BTU, R-32 refrigerant, black finish, 40 x 30 x 11 inches
GE Profile PLHS13XAHB Low Profile RV Air Conditioner With R32 And Heat Pump, 13,500 BTU, Black
 
Alternative Views:


: $1,055.80
Part Number: PLHS13XAHB
Manufacturer: GE Appliances

Quantity in Stock :

Free Shipping
Availability: Out of Stock
Qty:

 
GE Profile 13,500 BTU Heat Pump + Cooling GE Profile PLHS13XAHB Low-Profile RV Rooftop Air Conditioner with Heat Pump -- Black

The GE Profile PLHS13XAHB brings true four-season climate control to your RV rooftop in a low-profile 11-inch package. It cools with 13,500 BTU of capacity and heats efficiently down to 25 deg F using an advanced R-32 heat pump -- reducing your dependence on propane when temperatures dip. Designed for a standard 14-3/8 in. square roof opening, this unit fits the widest range of Class A, Class C, and fifth-wheel applications without a custom adapter.

Year-Round Comfort Without the Propane Bill

Most RV air conditioners only cool. The PLHS13XAHB adds a heat pump that efficiently extracts warmth from outdoor air and delivers it inside -- even when outside temperatures are as low as 25 deg F. Below that threshold, the unit automatically switches over to auxiliary heating so you're never left shivering waiting for a mode change.

R-32 refrigerant is the refrigerant of choice in modern high-efficiency equipment. Compared to the R-410A still found in many competing units, R-32 has a lower global warming potential and improved thermodynamic efficiency -- meaning the compressor does less work to move the same amount of heat. For full-timers and extended-season campers, that translates to measurable savings on shore power and reduced generator run time.

Heat Pump Down to 25 deg F

Automatic changeover to auxiliary heat below 25 deg F keeps you warm without manually switching modes or firing up the propane furnace.

Low-Profile Rooftop Design

At 11 inches tall, the PLHS13XAHB clears most campground height barriers and reduces aerodynamic drag compared to taller conventional units.

R-32 Refrigerant

Next-generation refrigerant delivers higher efficiency and a lower environmental footprint than older R-22 or R-410A systems still in the market.

Quiet Operation

Engineered for reduced noise output -- a practical priority in campgrounds where sound carries and a good night's sleep depends on it.

Roof Opening and Ceiling Clearance

The PLHS13XAHB is built around the industry-standard 14-3/8 in. x 14-3/8 in. square roof cutout with a +/- 1/4 in. variance tolerance. This matches the opening found on the vast majority of Class A motorhomes, Class C motorhomes, fifth wheels, and travel trailers built after the mid-1980s.

Required ceiling-to-roof clearance is 2 to 6 inches. This range accommodates most RV ceiling configurations without modification. If your ceiling-to-roof gap falls outside this range, verify the fit before ordering -- units outside the clearance range require a different ceiling assembly or duct adapter.

Propane Savings in Cold Weather

Running a heat pump at 35-40 deg F is significantly more efficient than burning propane in a forced-air furnace. The PLHS13XAHB lets you stretch a propane tank further on shoulder-season trips where temperatures stay above 25 deg F overnight.

Multiple Heating Modes

The unit supports multiple heating configurations to match conditions:

  • Heat Pump Mode -- primary heating using refrigerant cycle, most efficient when outdoor temps are above 25 deg F
  • Auxiliary Heat Mode -- activates automatically when heat pump efficiency drops below the 25 deg F threshold
  • Auto Changeover -- the unit selects the appropriate heating method based on outdoor temperature without user input

Electrical Requirements

The PLHS13XAHB runs on 115V AC / 20-amp dedicated circuit. This is standard for RV shore power hookups and compatible with most 30-amp and 50-amp RV service configurations when wired correctly through the distribution panel. A dedicated 20-amp breaker is required -- do not share this circuit with other high-draw appliances.

Shore Power and Generator Use

At 13,500 BTU, the PLHS13XAHB draws significant amperage during compressor start. If running on a generator, verify the generator's surge capacity can handle compressor startup loads. A soft-start module (sold separately) can reduce startup amp draw and is recommended for generators under 3,500W rated output.

Installation Notes

  • Fits standard 14-3/8 in. x 14-3/8 in. roof opening (+/- 1/4 in.)
  • Ceiling-to-roof clearance must be between 2 and 6 inches
  • Unit weight is 86 lbs -- two-person installation is strongly recommended for roof safety
  • A compatible ceiling assembly/control box is required for interior mounting and thermostat connection (verify compatibility with your existing ceiling assembly or order the matching GE Profile ceiling kit)
  • Rooftop gasket/seal should be inspected and replaced if worn during installation to prevent water intrusion
  • Refer to the GE Profile PLHS13XAHB instruction manual for wiring diagrams and torque specs
Ceiling Assembly Compatibility

The PLHS13XAHB rooftop unit requires a compatible GE Profile ceiling assembly for full thermostat and mode control. Confirm your existing ceiling assembly is compatible before installing this unit as a replacement. Using a non-matched ceiling assembly may limit available operating modes or void warranty coverage.

Warranty

GE Appliances backs the PLHS13XAHB with a 2-year manufacturer's warranty covering parts and labor. Warranty service is handled through GE Appliances authorized service channels.

Seasonal Maintenance Tips
  • Clean or replace the return air filter every 30 days of active use to maintain airflow and efficiency
  • Inspect the rooftop shroud for cracks or UV degradation each spring before cooling season
  • Keep the condensate drain path clear to prevent water backup into the ceiling assembly
  • Before winter storage, run the fan-only mode for 30 minutes to dry the evaporator coil and prevent mold growth

Product Identification

ManufacturerGE Appliances
Brand LineGE Profile
Model NumberPLHS13XAHB
SKUPLH13XAHB
UPC084691919896
Color / FinishBlack

Capacity and Performance

Cooling Capacity13,500 BTU
Heat Pump HeatingYes -- operational to 25 deg F
Auto Heat ChangeoverSwitches to auxiliary heat below 25 deg F
Refrigerant TypeR-32
Operating ModesCool, Heat Pump, Auxiliary Heat, Auto, Fan Only

Electrical Specifications

Voltage115V AC
Required Circuit Breaker20 Amp dedicated
Power SourceShore power or generator (115V AC)

Physical Dimensions

Overall Length40 in.
Overall Width30 in.
Overall Height (profile)11 in.
Unit Weight86 lbs
Roof Opening Required14-3/8 in. x 14-3/8 in. square (+/- 1/4 in.)
Ceiling-to-Roof Clearance2 to 6 inches required

Installation and Compatibility

Standard Roof Opening14-3/8 in. x 14-3/8 in. (industry standard)
Compatible RV TypesClass A, Class C, fifth wheel, travel trailer
Ceiling Assembly RequiredYes -- compatible GE Profile ceiling kit required (sold separately if not included)
Soft-Start CompatibleYes (soft-start module sold separately; recommended for generator use)

Warranty and Documentation

Warranty2-year manufacturer's warranty -- parts and labor
Warranty ServiceGE Appliances authorized service network
Instruction ManualAvailable from GE Appliances product support (PLHS13XAHB)
Important Information -- Read Before Ordering or Installing
  • Unit weight is 86 lbs. Two-person installation is required. Do not attempt solo rooftop installation.
  • A dedicated 20-amp circuit breaker is required. Do not share this circuit with other high-current appliances.
  • Ceiling-to-roof clearance must be between 2 and 6 inches. Verify your RV's clearance before purchase.
  • Roof opening must be 14-3/8 in. x 14-3/8 in. (+/- 1/4 in.). Non-standard openings require a roof adapter (not included).
  • A compatible GE Profile ceiling assembly is required for thermostat and mode control. Confirm ceiling assembly compatibility before ordering this rooftop unit.
  • Heat pump operation ceases below 25 deg F outdoor temperature. Auxiliary heat takes over automatically, but heat output capacity in extreme cold is reduced compared to a propane furnace.
  • R-32 refrigerant is mildly flammable (A2L classification). Service must be performed by a certified HVAC/R technician. Do not attempt refrigerant service yourself.
  • Running on a generator: verify your generator can supply sufficient surge current for compressor startup. A soft-start module is strongly recommended for generators under 3,500W.
  • Rooftop gasket/seal is critical for waterproofing. Inspect and replace if damaged during or after installation.
⚠️ WARNING: This product can expose you to one or more chemicals known to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


Browse for more RV Accessories in the same category as this item:

Appliances > Air Conditioners
Appliances


$1.59