Home > Home & Marine Upgrades > Home Furnace Parts >

Hayward FDXLBVS1930 Blower Vacuum Switch for Universal H-Series Pool Heaters | NBK 20410K

Hayward FDXLBVS1930 blower vacuum switch for Universal H-Series pool heaters H150FDN through H400FDP, NBK part 20410K
Hayward Blower Vacuum Switch For Pool Heaters
 
List Price: $35.00
: $19.94
You save $15.06!
Part Number: FDXLBVS1930
Manufacturer: Hayward

Quantity in Stock :8

Availability: In Stock
Qty:

 
Hayward OEM FDXLBVS1930 Fits H150-H400 FDN/FDP Hayward FDXLBVS1930 Blower Vacuum Switch for Universal H-Series Pool Heaters

The FDXLBVS1930 is a genuine Hayward replacement blower vacuum switch engineered specifically for Universal H-Series pool heaters rated from 150,000 to 400,000 BTU. This safety switch monitors negative pressure (vacuum) generated by the blower to confirm proper airflow before allowing ignition -- protecting the heat exchanger and combustion chamber from damage caused by blocked or restricted venting. Also catalogued as NBK Parts number 20410K, this is a direct drop-in replacement requiring no modifications.

Direct OEM Replacement for Hayward H-Series Pool Heaters

Pool heater vacuum switches are a common wear item and a frequent cause of ignition lockout faults. When the blower vacuum switch fails or loses calibration, the heater's control board reads insufficient airflow and refuses to light -- even when the blower motor itself is running fine. Replacing the switch with a genuine Hayward FDXLBVS1930 restores proper pressure sensing and gets the heater firing reliably again.

This switch is compatible with all 12 models in the Universal H-Series FDN (natural gas) and FDP (propane) lineup, from the H150 through the H400. If your heater displays an ignition error or AFS (air flow switch) fault code and the blower is spinning normally, this switch is the first part to inspect and replace.

Genuine Hayward OEM Part

FDXLBVS1930 is a factory Hayward component, also listed under NBK part number 20410K. Exact fit, no adapters or modifications needed.

Wide BTU Range Coverage

Fits all H-Series models from 150,000 BTU through 400,000 BTU -- both natural gas (FDN) and propane (FDP) configurations.

Airflow Safety Function

Monitors blower-generated vacuum to confirm adequate combustion airflow before ignition, protecting the heat exchanger and preventing unsafe operation.

Resolves Ignition Lockout

A failed vacuum switch is a leading cause of AFS fault codes on H-Series heaters. Replacing this switch often resolves no-heat calls without replacing the control board.

How the Blower Vacuum Switch Works

When the heater calls for heat, the blower motor starts first. As the blower spins up, it creates a measurable negative pressure (vacuum) in the combustion air path. The vacuum switch is a pressure-differential device wired into the ignition control circuit. Once the vacuum reaches the switch's setpoint, the contacts close, signaling the control board that airflow is confirmed and ignition can proceed.

If the switch contacts fail to close -- due to a faulty diaphragm, corroded contacts, a cracked pressure port, or a shift in calibration -- the board interprets the open circuit as an airflow fault and locks out ignition. Inspecting and replacing the FDXLBVS1930 is the correct diagnostic step before condemning the blower motor or control board.

Also Listed As NBK 20410K
If you sourced your original part from a pool supply distributor using the NBK catalog, part number 20410K is the same component as Hayward FDXLBVS1930. Both numbers reference this exact switch.

Common Symptoms of a Failed Vacuum Switch

  • Heater displays AFS, AF, or airflow fault code on the digital display
  • Blower motor runs but ignition never initiates
  • Heater goes through pre-purge cycle and then locks out
  • Intermittent heating -- works sometimes, faults others (early diaphragm fatigue)
  • Visible cracking or moisture in the vacuum hose connected to the switch
Diagnostic Tip
Before replacing the switch, inspect the small rubber vacuum hose connecting the switch to the blower housing. A cracked, kinked, or disconnected hose causes the same fault code as a failed switch. Replace the hose if damaged -- it is inexpensive and often overlooked.

Compatible Models -- Full Fitment List

The FDXLBVS1930 fits the following Hayward Universal H-Series pool and spa heater models:

  • H150FDN / H150FDP
  • H200FDN / H200FDP
  • H250FDN / H250FDP
  • H300FDN / H300FDP
  • H350FDN / H350FDP
  • H400FDN / H400FDP

FDN = Natural Gas configuration. FDP = Liquid Propane configuration. Both gas types use the same vacuum switch.

Maintenance Note
Pool heater vacuum switches are exposed to heat cycling, humidity, and pool chemical vapors over time. If your heater is more than 5 years old and has never had this switch replaced, consider including it in a seasonal start-up inspection -- especially if the unit is slow to ignite or trips the AFS fault intermittently.
Installation Heads-Up
Disconnect power to the heater at the breaker before servicing any components. Note the orientation and routing of the vacuum hose and wiring harness connector before removing the old switch to ensure correct reassembly.

Part Identification

Hayward Part NumberFDXLBVS1930
NBK Cross-Reference20410K
ManufacturerHayward Pool Products
Part TypeBlower Vacuum Switch (Air Flow Switch)
OEM or AftermarketOEM Hayward replacement

Physical Specifications

Shipping Weight4.8 lbs.
Component FunctionDifferential pressure / vacuum sensing switch
Mounting StyleDirect OEM bracket mount (replaces existing switch)

Heater Compatibility

Product LineHayward Universal H-Series
BTU Range Covered150,000 BTU to 400,000 BTU
Gas TypesNatural Gas (FDN) and Propane (FDP)
Compatible ModelsH150, H200, H250, H300, H350, H400 -- FDN and FDP variants

What Is Included

In the Box1x FDXLBVS1930 blower vacuum switch
Vacuum HoseNot included -- inspect and reuse or replace separately
HardwareNot included -- reuse existing mounting hardware

Application Context

Typical UseResidential and light commercial pool and spa heaters
Heater TypeGas-fired forced-draft (induced combustion)
Service CategoryIgnition system / safety interlock
Important Information
  • Always shut off power to the pool heater at the circuit breaker before replacing this switch. Do not work on live equipment.
  • If your gas supply is natural gas, confirm your heater model ends in FDN. If propane, confirm FDP. The vacuum switch fits both -- but verify your heater model is in the compatibility list above before ordering.
  • This switch does not include the vacuum hose, wiring harness connector, or mounting screws. Reuse original hardware or source replacements separately.
  • A vacuum switch fault code can also be caused by a blocked flue, dirty heat exchanger, or restricted air intake -- not just a failed switch. Perform a full visual inspection before replacing parts.
  • This is an OEM Hayward part intended for use by qualified pool service technicians or experienced DIY owners familiar with gas appliance service procedures.


Browse for more RV Accessories in the same category as this item: