Home > Appliances > Furnaces & Heaters >

M.C. Enterprises 233103MC RV Furnace Blower Motor for Suburban SF-42 / SF-42F -- 12V 3500 RPM

M.C. Enterprises 233103MC 12V 3500 RPM replacement blower motor for Suburban SF-42 and SF-42F RV furnaces, replaces OEM part 232212
M.C. Enterprises RV Furnace Motor For Suburban SF-42/42F
 
List Price: $160.00
: $87.99
You save $72.01!
Part Number: 233103MC
Manufacturer: M.C. Enterprises

Quantity in Stock :34

Availability: In Stock
Qty:

 
M.C. Enterprises12V DC / 3500 RPMReplaces OEM 232212233103MC Replacement Blower Motor for Suburban SF-42 and SF-42F RV Furnaces

If your Suburban SF-42 or SF-42F furnace has stopped pushing heat or the blower has failed, the 233103MC from M.C. Enterprises is the direct-replacement motor you need. Engineered to match the original 2-1/2" motor used in pre-2001 Suburban forced-air furnaces, this unit restores full blower function without modification. Also sold under NBK Parts number 20510.

Direct-Fit Blower Motor for Suburban SF-42 Series Furnaces

Suburban SF-42 and SF-42F furnaces are among the most common forced-air propane heaters found in older RVs, fifth wheels, and travel trailers. Over time, the blower motor wears out -- bearings fail, windings overheat, or the motor simply stops spinning. The M.C. Enterprises 233103MC is purpose-built to replace the original 232212 motor in units manufactured prior to 2001, with identical shaft lengths, case diameter, and electrical specs so the swap is straightforward.

At 12V DC and 3500 RPM, this motor delivers the airflow performance your furnace was designed around. Both shaft ends are usable, with primary and secondary shaft lengths matching the factory configuration for direct coupling to the blower wheel without adapter hardware.

Direct OEM Replacement

Replaces Suburban OEM part number 232212. Matches original mounting, shaft, and electrical specs for pre-2001 SF-42 and SF-42F furnaces.

12V DC Operation

Runs directly off the RV house battery system at 12 volts DC -- no inverter or converter modification needed.

Dual-Shaft Design

Primary shaft at 1-15/16" and secondary shaft at 1-1/2" match the factory blower wheel coupling on both motor ends.

Pre-2001 Fitment

Correct motor size (2-1/2" nominal) for Suburban SF-42 furnaces built before January 2001. Use your serial number to confirm build year before ordering.

Also Known As: NBK Parts 20510

This motor is cross-listed under NBK Parts number 20510. If you sourced this part number from a service manual or dealer parts lookup, this is the same unit.

How to Read Your Suburban Furnace Serial Number

Suburban furnaces manufactured after January 1990 carry a nine-digit serial number. The first two digits indicate the year of manufacture, the next digits indicate the production week, and the remaining digits are sequential serial numbers. For example, a serial number beginning with "98" indicates a 1998 build -- which is prior to 2001 and compatible with this motor. A serial number beginning with "01" or higher indicates a 2001 or later build, which may use a different motor specification. Always confirm your build year from the serial number before purchasing.

Verify Fitment Before Ordering

This motor is designed specifically for the SF-42 and SF-42F models using the 2-1/2" motor, built prior to 2001. Other Suburban furnace models (including the SF-30, SF-35, SF-25, and later SF-42 variants) use different motors with different case diameters, shaft configurations, or voltage specs. Do not assume fitment based on furnace BTU rating alone -- confirm by matching part number 232212 or verifying your serial number indicates a pre-2001 unit.

Installation Tips
  • Disconnect 12V power and shut off propane before beginning any furnace motor work.
  • Label all wiring connections before removing the old motor -- Suburban blower motors typically use two to three wires (ground, 12V supply, and sometimes a speed tap).
  • Inspect the blower wheel for debris or damage before reinstalling -- a damaged wheel can unbalance the new motor and shorten its service life.
  • After installation, run the furnace through at least one full heat cycle and check for unusual noise or vibration before returning to regular use.

Electrical Specifications

Voltage12V DC
Motor Speed3500 RPM
Application Voltage12V RV house battery system

Physical Dimensions

Motor Case Length4-1/2 inches
Motor Case Diameter2-3/8 inches
Nominal Motor Size2-1/2 inch (as used in SF-42 / SF-42F)
Primary Shaft Length1-15/16 inches
Secondary Shaft Length1-1/2 inches
Weight5 lbs

Fitment and Compatibility

Compatible Furnace ModelsSuburban SF-42, SF-42F
Build Date RangePre-2001 production units
OEM Part ReplacedSuburban 232212

Part Numbers and Cross-References

M.C. Enterprises Part Number233103MC
NBK Parts Cross-Reference20510
UPC815254022049
RV Upgrade Store SKU42-0835

Warranty

Manufacturer WarrantyLimited 90-day manufacturer warranty
Important Information
  • This motor fits ONLY Suburban SF-42 and SF-42F furnaces manufactured BEFORE 2001. It is not a universal blower motor.
  • Confirm your furnace serial number begins with a two-digit year code of 00 or lower (e.g., 98, 99, 00) before purchasing.
  • Do not use this motor as a replacement for other Suburban furnace models -- case diameter, shaft length, and RPM may differ.
  • Always disconnect 12V power at the battery and close the propane supply valve before working on any furnace component.
  • This listing is for the motor only. Blower wheel, mounting hardware, and wiring harness are not included.
  • Limited 90-day warranty applies to manufacturer defects. Damage from incorrect installation or voltage mismatch is not covered.
How does the furnace blower motor work?
Once the air inside the furnace is heated the blower motor will run the fan, allowing the warm air to be dispersed, heating up the inside of your RV to the set temperature. If you are not feeling the warm air circulating, then the furnace motor may need to be replaced.

ACCESSORIES
Suburban 521099 12V DC 3G DSI Fan Control Board for SF and NT Series RV Furnaces -- NBK 20210
: $89.99

Add
Suburban 521099 12V DC 3G DSI fan control board for SF and NT series RV furnaces, replaces 520820 and 232613, NBK part 20210


Browse for more RV Accessories in the same category as this item:

Appliances > Furnaces & Heaters
Appliances