Home > Home & Marine Upgrades > Wood & Pellet Stove Parts >

Enviro EF-016 High Limit Temperature Sensor for Enviro Pellet Stoves -- Part 20107

Enviro EF-016 high limit temperature sensor part 20107 for Enviro pellet stoves including EF1 EF2 EF3 Empress M55 MAXX Meridian and Windsor models
Enviro High Limit Temperature Sensor For Enviro Pellet Stoves
 
List Price: $25.88
: $15.02
You save $10.86!
Part Number: EF-016
Manufacturer: Enviro

Quantity in Stock :9

Availability: In Stock
Qty:

 
Enviro Part 20107 OEM Replacement Enviro EF-016 High Limit Temperature Sensor -- Part 20107

Keep your Enviro pellet stove running safely and efficiently with this direct-replacement high limit temperature sensor. The EF-016 (also cataloged as NBK Parts 20107) is the factory-specified sensor for a wide range of Enviro pellet stove models, protecting the stove by cutting power to critical components when exhaust or firebox temperatures exceed safe operating limits.

OEM-Grade Protection for Your Enviro Pellet Stove

The high limit temperature sensor is a critical safety component in any pellet stove. When the stove overheats -- due to a blocked exhaust vent, dirty burn pot, failed combustion blower, or other fault -- the high limit sensor triggers a shutdown before temperatures reach a damaging or dangerous level. A failed or out-of-spec sensor can cause nuisance shutdowns during normal operation or, worse, fail to shut down when a real overheat occurs.

Replacing a suspect or confirmed-faulty high limit sensor with a genuine Enviro EF-016 restores the factory safety threshold and eliminates guesswork. This part is a compact, low-weight component (0.1 lb.) that installs without specialized tools in most models.

Broad Model Coverage

Fits EF1 through EF5, Empress FS, Empress Insert, M55 series, MAXX series, Meridian, Milan, Mini, Omega, Solus, and Windsor -- one part covers most of the Enviro lineup.

Safety Shutdown Function

Monitors stove temperature and triggers a protective shutoff when limits are exceeded, preventing damage to the heat exchanger, auger motor, and control board.

Direct OEM Replacement

Matches the original factory specification. No modifications or adapters required for covered models. Replaces worn or failed sensors with confidence.

Compact and Lightweight

Weighs only 0.1 lb. Easy to ship, store as a spare, and install. A sensible part to keep on hand before heating season begins.

What the High Limit Sensor Does

Enviro pellet stoves use a bimetallic or thermal-disc high limit sensor mounted on or near the heat exchanger or exhaust plenum. When the sensed temperature rises above the sensor's rated trip point, the sensor opens its circuit, cutting power to the auger or convection blower and initiating a controlled shutdown. Once the stove cools below the reset threshold, many sensors automatically reset, allowing a restart attempt.

Common symptoms of a faulty high limit sensor include:

  • Stove shuts off randomly during normal operation at low or medium heat settings
  • Stove will not start and displays an overheat or high-limit fault code
  • Stove runs briefly then cuts out before reaching operating temperature
  • Sensor body shows visible heat discoloration, cracking, or corrosion

Before replacing the sensor, verify that the exhaust vent and air intake are clear, the burn pot is clean, and the combustion blower is operating at full speed. A sensor that trips repeatedly may be responding correctly to an underlying airflow or maintenance issue.

Also Known As: NBK Parts 20107. If you have sourced this part through an HVAC or hearth distributor under that catalog number, this is the same component.

Compatible Enviro Pellet Stove Models

The EF-016 is confirmed to fit the following Enviro pellet stove models:

  • EF1
  • EF2
  • EF3
  • EF3Bi
  • EF4
  • EF5
  • Empress FS
  • Empress Insert
  • M55 Cast FPI
  • M55 Cast
  • M55
  • MAXX-1
  • MAXX-B
  • MAXX-M
  • Meridian
  • Milan
  • Mini
  • Omega
  • Solus
  • Windsor
Not sure if this fits your stove? Cross-reference the part number printed on your existing sensor or check your stove's wiring diagram. The sensor is typically mounted on the exhaust plenum or heat exchanger housing and will have the Enviro part number stamped or labeled on the sensor body or its wiring harness tag.
Maintenance Tip: Replace the high limit sensor as part of an annual pre-season inspection if the stove is more than 5-7 years old or has had repeated high-limit shutdowns. Thermal sensors can drift out of spec over time due to heat cycling, leading to nuisance trips or, in rare cases, a sensor that no longer opens the circuit reliably.

Installation Overview

Installation is straightforward on all covered models. Disconnect stove power, allow the unit to cool completely, locate the sensor on the exhaust plenum or heat exchanger, disconnect the two-wire connector, remove the mounting screws or clip, and reverse the steps with the new sensor. No soldering or special tools are required for most models. Torque mounting fasteners snugly -- do not overtighten, as the sensor housing can crack.

Heads Up: Always disconnect the stove from AC power and allow it to cool to room temperature before accessing internal components. Pellet stove interiors retain heat for an extended period after shutdown.

Part Identification

ManufacturerEnviro
Part NumberEF-016
SKU / Vendor Part20107
Also Cataloged AsNBK Parts 20107
Component TypeHigh Limit Temperature Sensor

Physical Specifications

Weight0.1 lb.
Connector TypeTwo-wire disconnect (standard Enviro harness)
MountingScrew or clip mount, varies by model

Function and Operation

Sensor FunctionOpens circuit on overtemperature to initiate shutdown
Reset TypeAutomatic (thermal reset on cool-down, typical of Enviro series)
ApplicationPellet stove exhaust plenum / heat exchanger monitoring

Compatible Model List

EF SeriesEF1, EF2, EF3, EF3Bi, EF4, EF5
Empress SeriesEmpress FS, Empress Insert
M55 SeriesM55, M55 Cast, M55 Cast FPI
MAXX SeriesMAXX-1, MAXX-B, MAXX-M
Additional ModelsMeridian, Milan, Mini, Omega, Solus, Windsor

What Is Included

Included1x EF-016 high limit temperature sensor
Not IncludedMounting hardware, wiring harness, installation tools
Important Information
  • Disconnect the stove from AC power and allow it to cool completely before beginning any repair or replacement work.
  • This sensor is designed specifically for Enviro-brand pellet stoves. Do not use as a substitute for sensors in other brands without verifying identical trip-point ratings and connector compatibility.
  • A high limit sensor that trips repeatedly may indicate an underlying issue -- blocked vent, dirty burn pot, or failed combustion blower -- not just a failed sensor. Diagnose the root cause before assuming sensor replacement alone will resolve the problem.
  • Verify your model number against the compatibility list above before ordering. Enviro stove model and serial information is typically found on a label inside the hopper lid or on the rear panel of the stove.
  • Mounting hardware is not included. Retain and reuse original fasteners, or source appropriate replacements if damaged.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Wood & Pellet Stove Parts
Home & Marine Upgrades


$30.49