Home > Home & Marine Upgrades > Wood & Pellet Stove Parts >

Lennox H5889 Vacuum Pressure Switch for Bella, Winslow PI40 and PS40 Pellet Stoves -- NBK 20212

Lennox H5889 vacuum pressure switch NBK 20212 for Winslow PI40 PS40 and Bella pellet stoves, direct-fit OEM-spec replacement part
Lennox Vacuum Pressure Switch For Pellet Stoves
 
List Price: $39.99
: $23.09
You save $16.90!
Part Number: H5889
Manufacturer: Lennox

Quantity in Stock :2

Availability: In Stock
Qty:

 
LennoxPart H5889 / NBK 20212Direct-Fit ReplacementLennox H5889 Vacuum Pressure Switch for Pellet Stoves

If your pellet stove is failing to light, shutting down unexpectedly, or refusing to run the combustion blower circuit, a failed vacuum pressure switch is one of the first components to check. The Lennox H5889 is the correct OEM-spec replacement switch for Lennox Bella, Winslow PI40, and Winslow PS40 pellet stoves. It monitors negative pressure (draft) produced by the combustion blower and signals the control board that proper airflow is present before allowing the ignition sequence to continue. Sold individually and also cross-referenced as NBK Parts number 20212.

Why the Vacuum Pressure Switch Matters in Your Pellet Stove

Pellet stoves use a sealed combustion chamber and a dedicated combustion (exhaust) blower to create a controlled draft. The vacuum pressure switch is a safety interlock -- it confirms that the blower is running and generating adequate negative pressure before the control board proceeds with ignition. If the switch fails open, the stove will not light or will fault out immediately. If it fails closed, it can create an unsafe condition by signaling airflow when none is present.

Common symptoms of a failed H5889 switch include a stove that clicks through the start cycle but never ignites, an "air flow" or "draft" fault code on the control board, or a stove that lights briefly and then shuts off. Replacing this low-cost switch is a logical first diagnostic step before condemning the combustion blower motor.

Correct Close Setpoint

Closes at .10 inches water column (WC PF), matching the factory specification for the Bella, PI40, and PS40 combustion systems.

OEM-Spec Fitment

Designed to drop into the existing switch bracket and hose barb connection on compatible Lennox and Winslow pellet stove models -- no modifications needed.

Safety Interlock Function

Prevents ignition when combustion airflow is insufficient, protecting the stove and the flue system from incomplete combustion conditions.

Dual Cross-Reference

Listed under both Lennox part number H5889 and NBK Parts number 20212, making it easy to verify you have the correct replacement before ordering.

Direct Replacement Confidence: The H5889 is specifically engineered for the Lennox Bella, Winslow PI40, and Winslow PS40 pellet stove platforms. If your stove is one of these models and the vacuum pressure switch has been confirmed faulty with a multimeter, this part replaces it exactly without adaptation.
How to Test the Existing Switch Before Ordering: Disconnect power to the stove. Locate the small pressure switch (usually near the combustion blower outlet, connected by a short rubber hose and two spade-terminal wires). Using a multimeter set to continuity, check across the switch terminals at rest -- the switch should be open (no continuity) with no vacuum applied. Apply a small amount of suction to the hose port (a clean piece of tubing and gentle mouth suction works) -- the switch should click closed (continuity present). If the switch stays open under suction, or stays closed at rest, replace it.
Verify Your Model Before Installing: This switch is rated and calibrated specifically for the Bella, PI40, and PS40 models. Using a pressure switch with a different setpoint in another pellet stove model may result in nuisance lockouts or, more seriously, failure to lockout under low-draft conditions. Confirm model compatibility before installation.
Maintenance Note: While replacing the switch, inspect the short rubber vacuum hose connecting the switch to the combustion blower port. These hoses can crack, harden, or pull off at the barb fittings over time, causing the same symptoms as a failed switch. A cracked hose is a common misdiagnosis -- replace the hose if it shows any signs of brittleness or heat damage.

Part Identification

Lennox Part NumberH5889
NBK Cross-Reference20212
Component TypeVacuum (Negative Pressure) Switch
FunctionCombustion blower draft safety interlock

Switch Specifications

Close Setpoint.10 inches water column (WC PF)
Switch ActionNormally open, closes on sufficient negative pressure
Weight0.5 lbs

Compatibility

Lennox BellaCompatible -- direct replacement
Winslow PI40Compatible -- direct replacement
Winslow PS40Compatible -- direct replacement

In the Box

Included1x Lennox H5889 vacuum pressure switch
Not IncludedVacuum hose, wire connectors, mounting hardware
Important Information
  • Always disconnect power to the pellet stove before removing or installing any components.
  • This switch is calibrated for .10 WC PF -- do not substitute a switch with a different setpoint, as this will affect safety interlock function.
  • Compatible models are Lennox Bella, Winslow PI40, and Winslow PS40 only. Confirm your model before installation.
  • Inspect the vacuum hose and hose barb connections during replacement -- a leaking hose will cause the new switch to behave identically to the failed one.
  • If replacing this switch does not resolve the fault, test the combustion blower motor for proper RPM and amperage draw before assuming the control board has failed.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Wood & Pellet Stove Parts
Home & Marine Upgrades