Home > Home & Marine Upgrades > Blower Motors >

Dayton 1TDP4 Replacement Blower Motor 71 CFM 1580 RPM 115V Ball Bearing Replaces 2C067

Dayton 1TDP4 replacement blower motor 71 CFM 1580 RPM 115V ball bearing squirrel cage direct replacement for 2C067
Dayton Blower Motor, 71 CFM, 1580 RPM, 115V
 
List Price: $120.99
: $86.49
You save $34.50!
Part Number: 1TDP4
Manufacturer: Dayton

Quantity in Stock :37

Availability: In Stock
Qty:

 
Dayton71 CFM / 115VReplaces 2C067Dayton 1TDP4 Replacement Blower Motor -- 71 CFM, 1580 RPM, 115V

The Dayton 1TDP4 is a direct-replacement squirrel cage blower motor designed to swap in where the original Dayton 2C067 has worn out or failed. At 71 CFM and 1580 RPM on a standard 115V/60 Hz circuit, it restores proper airflow to HVAC, ventilation, and climate-control systems without rewiring or fabrication. Ball bearings and Class B insulation mean this motor is built for continuous-duty use, not just occasional cycles.

Direct-Replacement Blower for Dayton 2C067 Applications

If your existing Dayton 2C067 blower motor has seized, overheated, or lost output, the 1TDP4 is the correct replacement. The dimensions, shaft size, rotation direction, and electrical specs match the original, so installation is a straightforward swap on compatible equipment. No adapter plates, no rewiring -- just disconnect, remove, install, and reconnect.

Also sold and catalogued as NBK Parts number 20496, so you may find it cross-referenced under either designation when sourcing through HVAC or parts distributors.

Ball Bearing Construction

Precision ball bearings on both ends of the shaft support longer service life and quieter operation compared to sleeve-bearing alternatives, especially in continuous-duty or high-temperature environments.

Automatic Overload Protection

Built-in thermal overload protection shuts the motor down if it exceeds safe operating temperature, then resets automatically -- protecting both the motor and downstream equipment.

Class B Insulation

Class B motor insulation is rated for continuous operation up to 130 deg C (266 deg F) winding temperature, well above what typical HVAC blower duty demands.

50/60 Hz Compatible

Rated for both 50 Hz and 60 Hz supply frequency, making this motor suitable for North American installations and compatible with most RV shore-power and generator sources.

Rotation and Airflow Direction

The 1TDP4 runs clockwise rotation when viewed from the inlet side. This matches the original 2C067 orientation. Verify your existing unit's rotation direction before ordering -- installing a motor with the wrong rotation reverses airflow through the blower housing and significantly reduces system performance.

Confirmed Direct Replacement: The 1TDP4 is the manufacturer-designated replacement for Dayton model 2C067. Shaft diameter, housing dimensions, rotation, and electrical specs are matched to the original. No modifications required for a direct swap.

Typical Applications

This blower motor is used in a range of forced-air applications where compact size and moderate airflow are needed:

  • HVAC air handling units and fan coil boxes
  • Ventilation cabinets and enclosure cooling
  • Small furnace blower replacement
  • RV or coach climate-control system blower replacement
  • Commercial refrigeration evaporator fan applications
Cross-Reference Note: This motor is catalogued as Dayton 1TDP4 and also as NBK Parts 20496. Both refer to the same unit. When sourcing parts, either number confirms you have the correct replacement.

Installation Notes

The 8 mm shaft diameter is standard for the 2C067 blower wheel. If you are reusing the existing blower wheel, verify the bore matches 8 mm before reassembly. Wheel diameter on the original application is 5-1/4 inches -- confirm clearance in your housing. The motor draws only 0.50A at 115V, so no dedicated high-amperage circuit is required; a standard 15A branch circuit is more than adequate.

Maintenance Tip: Ball bearing motors do not require routine lubrication under normal operating conditions. If the motor is being installed in a high-dust environment, check and clean the inlet screen or filter upstream of the blower periodically to prevent airflow restriction that can cause the thermal overload to trip repeatedly.
Max Inlet Temperature: Do not exceed 104 deg F (40 deg C) at the motor inlet. Operating above this limit risks premature bearing wear and may trigger the thermal overload protection under load.

Electrical Specifications

Voltage115V AC
Amperage0.50A
Frequency50/60 Hz
Insulation ClassClass B
Overload ProtectionAutomatic reset thermal overload

Performance Specifications

Airflow (CFM)71 CFM
Speed (RPM)1580 RPM
Rotation DirectionClockwise (viewed from inlet)
Max Inlet Temperature104 deg F (40 deg C)

Physical Dimensions

Overall Height7-7/8 in
Overall Width3-7/8 in
Overall Depth7-7/8 in
Inlet Diameter4-3/4 in
Outlet Height2-7/8 in
Outlet Width3-1/4 in
Wheel Diameter5-1/4 in
Shaft Diameter8 mm
Weight6 lbs

Bearing and Construction

Bearing TypeBall bearings (both ends)
Motor ClassClass B insulation
DutyContinuous

Part Number Cross-Reference

Dayton Part Number1TDP4
Replaces (Dayton)2C067
NBK Parts Number20496
Important Information
  • Maximum inlet air temperature is 104 deg F (40 deg C). Exceeding this rating can damage bearings and trigger repeated thermal shutdowns.
  • Rotation is clockwise when viewed from the inlet side. Confirm your application requires clockwise rotation before installing -- reversed rotation significantly degrades airflow and system performance.
  • Shaft diameter is 8 mm. Verify blower wheel bore before reassembly if reusing the existing wheel.
  • This motor is a direct replacement for Dayton 2C067 only. Verify application compatibility before ordering if replacing a different OEM motor.
  • Blower wheel/impeller is NOT included. This listing is for the motor only.
  • Disconnect and lock out power before removing or installing this motor.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Blower Motors
Home & Marine Upgrades