The interior half of your Furrion Chill system -- replace a damaged or failed ceiling assembly without pulling the rooftop unit. Built-in manual knobs put full control in your hand without requiring a wall thermostat, making this a straightforward drop-in for older-generation Furrion Chill R410A installations.
When your Furrion Chill rooftop AC is working fine but the interior ceiling assembly has cracked, lost a blower motor, or damaged its control board, the FACT11MA-PS lets you swap just the indoor section. No need to remove the rooftop condenser or reclaim refrigerant -- this is strictly the ceiling-mount evaporator and blower housing that installs from inside the coach.
Manual knob operation means the thermostat and fan speed are dialed in directly on the unit itself. There is no wall control harness to run and no smart-home pairing required -- ideal for older rigs or simplified electrical setups.
Thermostat and fan speed controlled directly on the unit. No wall thermostat wiring required.
Low, medium, and high blower settings for precise comfort across varying outside temps.
Directional louvers let you aim cooled air toward seating or sleeping areas as needed.
Two removable air filters capture dust and debris. Rinse and reinstall -- no replacements to order.
The FACT11MA-PS supports both ducted and non-ducted ceiling installations. In non-ducted mode, conditioned air flows directly out of the ceiling unit into the main living area. In ducted mode, the assembly connects to an existing duct distribution system, routing cool air to multiple vents throughout the coach. Confirm your current duct configuration before ordering to ensure the correct adapter plate is on hand.
The manual control design on the FACT11MA-PS is intentional. Older Furrion Chill installations did not include a digital wall controller, and this assembly matches that original configuration exactly. If you want to upgrade to digital or app-based control, Furrion offers separate controller-compatible ceiling assemblies -- but if you want a like-for-like swap, this is the correct unit.
The ceiling assembly mounts to the standard 14-inch RV roof opening from inside the coach. The unit is designed to accommodate roof thicknesses from 3 inches up to 6 inches, covering the range found in most fiberglass and aluminum-framed RV roofs. The electrical connection mates to the rooftop condenser unit via the existing wiring harness -- no new wiring runs are typically needed when replacing a like-for-like Furrion Chill ceiling assembly.
This ceiling assembly is designed and rated for use with R410A refrigerant. It is not compatible with older R22 systems or with the newer R32/low-GWP platforms. Verify your rooftop unit's refrigerant type on the compressor nameplate before purchasing.
Rinse the two mesh filters every 30 days of heavy use or at the start of each cooling season. Allow filters to dry completely before reinstalling -- a wet filter reduces airflow and can transfer moisture into the blower housing. Filters are retained by simple clips and do not require tools to remove.
The FACT11MA-PS ceiling assembly pairs with Furrion Chill rooftop AC units in the older-generation R410A product family, including models sold under the FAC series prefix. If your rooftop unit is a current-generation Furrion Chill with an integrated digital control or Bluetooth connectivity, verify the correct ceiling assembly part number before ordering -- the connectors and control protocols differ between generations.