Home > Home & Marine Upgrades > Blower Motors >

US Motors 5462H Condenser Fan Motor 208-230V 1075 RPM 1/6-1/3 HP PSC 5.6" Diameter TEAO

US Motors 5462H permanent split capacitor condenser fan motor, 5.6 inch diameter, 208-230V, 1075 RPM, TEAO enclosure with horizontal stud mount
US Motors Condenser Fan Motor, 208-230V, 1075 RPM, 1/6-1/3 HP
 
List Price: $200.01
: $110.49
You save $89.52!
Part Number: 5462H
Manufacturer: US Motors

Quantity in Stock :35

Free Shipping
Availability: In Stock
Qty:

 
US MotorsPSC Condenser Fan MotorTEAO EnclosureUS Motors 5462H Condenser Fan Motor -- 208-230V, 1075 RPM, 1/6-1/3 HP

The US Motors 5462H is a permanent split capacitor (PSC) condenser fan motor built for continuous-duty operation in commercial and residential HVAC condensing units. With a 5.6" frame, reversible rotation, dual-speed operation, and automatic thermal overload protection, it covers a wide range of condenser fan replacement applications where a reliable, direct-drive motor is needed.

Reliable PSC Motor for Condenser Fan Replacement

The 5462H is a workhorse replacement motor engineered to meet the demands of outdoor condensing units. Its totally enclosed air-over (TEAO) enclosure shields internal windings from the airstream contaminants common in outdoor HVAC environments -- dust, debris, and moisture. Class B insulation and automatic thermal overload protection keep the motor running safely even during high-ambient summer loads.

With dual-speed operation (two winding speeds), reversible shaft rotation, and a horizontal stud mount, this motor adapts to a range of OEM configurations without modification. The 48-inch lead length provides routing flexibility inside most condenser cabinets.

Also sold and stocked under the NBK Parts number 20587, making cross-referencing straightforward for HVAC technicians and parts distributors.

Reversible Rotation

Shaft rotation direction is field-selectable -- swap lead connections to match CW or CCW fan blade requirements without ordering a separate motor.

Continuous Duty Rated

Built for uninterrupted operation in demanding outdoor condensing applications, not just intermittent cycling.

Thermal Overload Protection

Automatic thermal overload cuts power if the motor overheats and resets automatically once it cools -- protecting windings from burnout.

TEAO Enclosure

Totally enclosed air-over construction keeps contaminants out of windings while relying on the condenser airstream for cooling -- the correct design for direct-drive fan duty.

Mounting and Installation Details

The 5462H uses a horizontal stud mount, the standard configuration for most residential and light commercial condenser units. The 5.6" diameter frame (48Y-style) matches the mounting footprint of many OEM condenser fan motors from Carrier, Trane, Lennox, Rheem, and York platforms, though always verify your unit's mounting hole pattern, shaft diameter, and blade pitch before installation.

Field Reversibility: Rotation direction is changed by swapping the motor leads per the wiring diagram on the motor label. No mechanical disassembly required. Confirm blade pitch and required airflow direction before wiring.

Capacitor Requirement

As a permanent split capacitor (PSC) motor, the 5462H requires an external run capacitor to operate. The correct capacitor value (microfarads and voltage rating) is printed on the motor nameplate. A mismatched or failed capacitor is one of the most common causes of PSC motor failure -- always replace the run capacitor when replacing the motor.

Run Capacitor: Not included. Match the microfarad (MFD) and voltage rating specified on the motor nameplate. Installing the motor without the correct run capacitor will result in reduced performance, overheating, or failure to start.

Cross-Reference and Compatibility

The 5462H is also cataloged and sold as NBK Parts number 20587. When cross-referencing, match the following to your existing motor nameplate to confirm compatibility:

  • Frame diameter: 5.6" (48Y frame equivalent)
  • Voltage: 208-230V single phase, 60 Hz
  • RPM: 1075
  • HP range: 1/6 to 1/3 HP
  • Enclosure type: TEAO
  • Mount type: Horizontal stud
  • Shaft specifications: Verify shaft diameter, length, and flat orientation against your existing motor before ordering
Maintenance Tip: Ball bearings in this motor are sealed and do not require periodic lubrication. If the motor develops bearing noise, replacement is the correct remedy -- do not attempt to re-lubricate sealed bearings by drilling or puncturing the bearing shield.
Pro Tip: When replacing a condenser fan motor, also inspect and replace the fan blade, run capacitor, and contactor as a set if the system has high run hours. Replacing just the motor in a worn system often leads to a repeat call.

Electrical Specifications

Voltage208-230V
PhaseSingle phase
Frequency60 Hz
Full Load Amps2.6A
Horsepower1/6 to 1/3 HP
RPM1075
Number of Speeds2
CapacitorExternal run capacitor required (not included)

Mechanical Specifications

Frame Diameter5.6 inches
Mount TypeHorizontal stud mount
Shaft RotationReversible (CW or CCW)
Bearing TypeBall bearings (sealed)
Lead Length48 inches
Weight19 lbs

Motor Construction

Motor TypePermanent Split Capacitor (PSC)
EnclosureTEAO (Totally Enclosed Air Over)
Duty CycleContinuous duty
Insulation ClassClass B
Thermal ProtectionAutomatic reset thermal overload
Ambient Temperature Rating140 deg F (60 deg C)

Part Numbers and Cross-Reference

US Motors Part Number5462H
NBK Parts Number20587
Vendor Part Number20587
Important Information
  • External run capacitor is NOT included -- match MFD and voltage rating to the motor nameplate before ordering.
  • Verify shaft diameter, shaft length, and flat orientation against your existing motor. Shaft specs are not interchangeable across all 5.6" frame motors.
  • Confirm mounting hole pattern on your unit matches the horizontal stud mount configuration before installation.
  • Always disconnect and lock out power before removing or installing the motor.
  • Fan blade pitch and required airflow direction must be confirmed before setting rotation direction via lead wiring.
  • Do not operate this motor without the correct run capacitor -- doing so will damage the windings and void any warranty.
  • This motor is rated for air-over (TEAO) cooling -- it must be installed in a ducted or direct airstream application. Do not use in still-air or ODP applications.


Browse for more RV Accessories in the same category as this item: