Genuine Lippert replacement Quick Level touch panel assembly for Ground Control TT, Ground Control 3.0, and Level-Up Hydraulic leveling systems. One-touch auto-level and jack retraction. Status indicator lights. Plug-and-play replacement — no wiring modifications required. Outdoor-rated construction. 3 lbs.
The Lippert 425306 is the genuine replacement Quick Level touch panel assembly for Lippert's family of automatic RV leveling systems — including Ground Control TT (travel trailer), Ground Control 3.0 (fifth wheel), and Level-Up Hydraulic systems. When the touch panel becomes unresponsive, develops dead zones on the touchpad surface, loses indicator light function, or suffers physical damage that prevents reliable leveling control, the 425306 restores full one-touch auto-leveling and jack retraction functionality with a plug-and-play replacement that requires no wiring modifications.
The Quick Level panel is the primary user interface for these leveling systems — it's the control you press to initiate automatic leveling when you pull into a campsite and to retract all jacks when you break camp. A failed or unreliable panel doesn't just cause inconvenience; it can leave you unable to level the coach automatically or, in some cases, unable to retract jacks to travel. The 425306 resolves panel failures quickly with a direct swap that reconnects to the existing harness at the same connector.
Connects to the existing wiring harness at the same connector — unplug the old panel, connect the new one, done. No wiring changes, no modifications
Single button activates the full automatic leveling sequence — the system levels the coach and stops without further input, just as the original panel did
Indicator lights display system status, operation feedback, and error conditions — same visual feedback as the original panel for consistent system monitoring
Built to withstand outdoor mounting environments — resists water, UV exposure, and corrosion for long-term reliable operation in the RV exterior or interior mounting location
The 425306 Quick Level Touch Panel is compatible with the following Lippert automatic leveling systems: Ground Control TT: Automatic leveling system for travel trailers. Uses Hall Effect jack motors with a touch panel control for one-touch setup and retraction. The 425306 is the replacement panel for this system. Ground Control 3.0: Automatic leveling system for fifth wheel RVs (LC358590, LC675817). Four Hall Effect electric jacks controlled by a touch panel and control module. The 425306 replaces the quick-level touch panel on this system — note that the Ground Control 3.0 touchscreen remote (LC358601) is a different component, for the larger separate remote display unit. Level-Up Hydraulic: Hydraulic automatic leveling system for fifth wheels and motorhomes. The 425306 Quick Level panel serves as the primary user interface for the Level-Up Hydraulic system's one-touch leveling and retraction functions. How to confirm compatibility: Visually match the button layout and connector of your existing panel against the 425306. If your existing panel is labeled "Quick Level" or uses the same single-connector harness attachment, the 425306 is the correct replacement. Contact Lippert at support.lci1.com with your RV VIN if you are uncertain which panel your system uses.
The touch panel is one of several components in the leveling system. Before ordering the 425306, confirm the panel is actually the failed component — not the control module, motor, or power supply: Signs the panel is the issue: • Touch panel is physically cracked, has water intrusion damage, or has areas that no longer respond to touch • Panel displays indicator lights but pressing buttons produces no system response • Panel shows no power (no lights, no display) when the RV is powered • Panel was physically damaged or impacted Signs the fault may be elsewhere (not the panel): • Panel responds to touch and displays lights, but jacks don't move — more likely a motor, control module, or battery issue • All jacks unresponsive with an error code — read the error code first (support.lci1.com) before replacing the panel • Battery voltage below 12.75V — low battery prevents the system from operating and looks like a panel or motor fault Simplest diagnostic step: Confirm the panel has power (indicator lights illuminate when the RV is on). If the panel has power but doesn't respond to touch input, the panel itself is the likely failure. If the panel has no power at all, check the system's wiring and fuse before assuming the panel is the fault.
The 425306 is a plug-and-play replacement — the simplest component swap in the leveling system. Tools Needed: Screwdriver (for mounting screws); no electrical tools required Key Steps: 1. Retract all jacks fully before beginning — ensure the RV is in travel position 2. Disconnect RV from shore power and turn off the leveling system 3. Remove the old panel — unscrew the mounting screws holding the panel to the wall or mounting bracket; note the panel's orientation 4. Disconnect the wiring harness connector from the back of the old panel — the connector typically releases with a squeeze-and-pull tab 5. Connect the 425306 — plug the harness connector into the new panel; the connector is keyed to prevent incorrect orientation 6. Mount the new panel in the same location and orientation using the original mounting screws 7. Restore power and test — confirm indicator lights illuminate; test auto-level function and jack retraction to verify full panel operation No calibration or programming is required after installation.
Included: • 425306 Quick Level Touch Panel Assembly • Mounting hardware NOT Included — May Need Separately: • Wiring harness extension (if the existing harness is damaged or too short for the mounting location) Related Leveling System Parts: • 421484 — Replacement touchpad for Ground Control 5th wheel and travel trailer leveling systems (different panel — verify your system uses 425306 vs. 421484 before ordering) • LC304136 — Ground Control 3.0 control module (4-point; replace if panel replacement doesn't resolve the fault) • 343758 — Replacement Hall Effect motor for Ground Control 3.0 jacks • LC358601 — Ground Control 3.0 replacement touchscreen remote with charger (the larger separate remote display — different from this 425306 panel) • 656216 — Replacement stabilizer motor and gearbox for Ground Control TT
Lippert Customer Care: Phone: 1-574-537-8900 Website: support.lci1.com Resources at support.lci1.com: • Ground Control TT, Ground Control 3.0, and Level-Up Hydraulic owner's manuals • Error code reference guides for each system • Leveling system troubleshooting guides To confirm compatibility: Contact Lippert with your RV VIN — they can confirm whether the 425306 is the correct touch panel for your specific leveling system and year. California Prop 65: This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. See P65Warnings.ca.gov.
The 425306 panel replacement resolves the specific failure mode where the panel itself — not the motors, control module, or power system — is the non-functional component. Always confirm the panel is the actual failed component before ordering to avoid an unnecessary purchase.
The 425306 and 421484 are two different touch panels that look similar in listing photos — the key is to visually match the button layout and connector on your existing panel before ordering. Contact Lippert at support.lci1.com or 1-574-537-8900 with your RV VIN to confirm which panel your specific system uses.