Home > Home & Marine Upgrades > Blower Motors >

Dayton 1TDP3 Replacement Blower Motor 75 CFM 3020 RPM 115V 60Hz Replaces 4C443

Dayton 1TDP3 replacement blower motor 75 CFM 3020 RPM 115V with 4-inch outlet flange and ball bearings, replaces Dayton 4C443
Dayton Blower Motor, 75 CFM, 3020 RPM, 115V
 
List Price: $122.49
: $87.49
You save $35.00!
Part Number: 1TDP3
Manufacturer: Dayton

Quantity in Stock :36

Availability: In Stock
Qty:

 
Dayton 75 CFM / 115V Replaces 4C443 & Fasco 7021-4931 Dayton 1TDP3 Replacement Blower Motor -- 75 CFM, 3020 RPM, 115V

The Dayton 1TDP3 is a direct-replacement blower motor engineered to swap in wherever the original Dayton 4C443 or Fasco 7021-4931 has failed. With a 75 CFM airflow rating, 3020 RPM output, and a 4-inch outlet flange, it restores proper ventilation and heat distribution without modification. Automatic overload protection and sealed ball bearings keep it running reliably over the long haul.

Direct-Fit Performance Where Your Old Motor Left Off

Blower motors in RV furnaces, air handlers, and ventilation units take a beating -- constant cycling, temperature swings, and vibration all accelerate wear. When your original Dayton 4C443 or Fasco 7021-4931 burns out or loses torque, the 1TDP3 steps in as a confirmed replacement without requiring new brackets, wiring harnesses, or adapters.

At 0.45 amps draw and 115V AC input, this motor is a light load on your shore power or generator circuit. The 60 Hz rating matches standard North American electrical systems, making it straightforward to wire into any existing single-phase AC setup.

75 CFM Airflow

Delivers consistent 75 cubic feet per minute to keep heat or conditioned air moving through the duct system at the designed rate.

Ball Bearing Construction

Sealed ball bearings reduce friction and resist wear far better than sleeve bearings, extending service life in high-cycle applications.

Automatic Overload Protection

Built-in thermal overload automatically cuts power if the motor overheats, then resets -- protecting the motor and your wiring.

4-Inch Outlet Flange

Standard 4-inch OD outlet flange connects directly to existing ductwork without reducers or adapters in most replacement scenarios.

Confirmed Replacement Models

This motor is a verified drop-in for the following original equipment parts:

  • Dayton 4C443 -- direct replacement
  • Fasco 7021-4931 -- direct replacement
  • Also cataloged under NBK Parts 20361

If your existing motor carries one of these part numbers on its label, the 1TDP3 is the correct replacement. Cross-reference your motor's voltage (115V), frequency (60 Hz), and outlet flange diameter (4 inches) before ordering if the label is damaged or missing.

Low Amp Draw, Easy Circuit Load
At only 0.45 amps, the 1TDP3 adds minimal load to your electrical system -- well within the capacity of any standard furnace or air handler circuit. No circuit upgrades required.

Inlet Temperature Rating

The 1TDP3 is rated for a maximum inlet air temperature of 104 deg F (40 deg C). This is important in furnace applications where return air or enclosure temperatures can climb. Ensure the motor is positioned to draw cooler ambient air rather than recirculated heated air to stay within this limit.

Temperature Limit Note: Do not install in locations where inlet air regularly exceeds 104 deg F. Sustained operation above this threshold will shorten motor life and may trip the overload protector repeatedly.

Installation Notes

The 1TDP3 is designed for straightforward replacement in systems that previously used the 4C443 or Fasco 7021-4931. Standard installation steps apply:

  • Disconnect all power before removing the old motor.
  • Note the rotation direction of the original motor wheel before removal -- confirm the replacement spins the same direction.
  • Match the outlet flange to your existing duct collar (4-inch OD).
  • Reconnect wiring to match original lead configuration (115V, single-phase, 60 Hz).
  • Restore power and verify airflow and RPM are normal before closing up panels.
Maintenance Tip: Before installing a new blower motor, clean the blower wheel and housing of any dust, debris, or corrosion. A dirty wheel causes imbalance that accelerates bearing wear on the new motor.

Common RV and HVAC Applications

The 1TDP3 is typically found in smaller forced-air furnaces, in-line duct fans, and ventilation air handlers that use 115V AC power. It is well-suited for:

  • RV and coach furnace blower assemblies (where 115V shore-power furnaces are used)
  • Residential and light commercial air handler units using Dayton or Fasco OEM motors
  • Portable or cabinet-style space heaters with blower assemblies
  • Ventilation equipment requiring a compact, low-draw 115V blower
Verify Your Voltage Before Ordering: This motor runs on 115V AC, 60 Hz only. It is not compatible with 12V DC RV systems, 24V systems, or 50 Hz electrical grids. If your rig runs a 12V DC furnace blower (common in propane furnaces), this is not the correct part.

Electrical Specifications

Voltage115V AC
Frequency60 Hz
Amperage0.45A
PhaseSingle-phase

Performance Specifications

Airflow (CFM)75 CFM
Motor Speed3020 RPM
Bearing TypeBall bearings
Overload ProtectionAutomatic thermal reset
Max Inlet Temperature104 deg F (40 deg C)

Physical Specifications

Outlet Flange OD4 inches
Weight6 lbs

Replacement / Compatibility

Replaces Dayton4C443
Replaces Fasco7021-4931
NBK Parts Cross20361
Manufacturer Part No.1TDP3
Vendor / SKU20361

Package Information

What's Included1x Dayton 1TDP3 blower motor
Mounting HardwareNot included -- reuse original hardware
Important Information -- Read Before Installing
  • This motor operates on 115V AC, 60 Hz only -- not compatible with 12V DC or 24V DC RV electrical systems.
  • Maximum inlet air temperature is 104 deg F. Do not expose the motor inlet to heated return air above this limit.
  • Disconnect shore power or generator power completely before removing the old motor or making any wiring connections.
  • Verify rotation direction matches your blower wheel before final installation -- reversing rotation reduces airflow and can damage the wheel.
  • Mounting hardware is not included -- retain and reuse the original hardware from your existing motor installation.
  • Confirm your existing motor is the Dayton 4C443 or Fasco 7021-4931 before purchasing -- installing an incorrect motor can cause blower assembly damage or inadequate airflow.


Browse for more RV Accessories in the same category as this item:

Home & Marine Upgrades > Blower Motors
Home & Marine Upgrades


$2.91