Dayton 223 CFM Class B Insulation Dayton 1TDU8 Replacement Blower Motor -- 223 CFM, 115V (NBK 20533)

The Dayton 1TDU8 is a direct replacement blower motor engineered to restore airflow in HVAC, furnace, and ventilation systems. Rated at 223 cubic feet per minute with dual-speed operation at 2600/2750 RPM, this 115V motor runs on both 50 and 60 Hz power and is also catalogued as NBK Parts number 20533. It replaces the discontinued Dayton model 4C826 on a drop-in basis.

Direct-Fit Replacement for Dayton 4C826 -- No Modifications Required

When your blower motor fails, a precise replacement matters. The 1TDU8 matches the physical envelope and electrical ratings of the original 4C826, so you can swap it in without rewiring or fabricating mounts. At 6 lbs and with a compact overall footprint of 14-3/4 in wide x 3-5/8 in deep x 4-3/4 in tall, it fits the same cavity as the unit it replaces.

Dual-speed operation (2600 RPM at 50 Hz / 2750 RPM at 60 Hz) and a low amp draw of 0.45/0.60A make this motor well suited for continuous-duty residential and light commercial HVAC applications. Class B insulation and ball bearings deliver long service life even in elevated-temperature environments.

Dual-Speed Operation

Runs at 2600 RPM (50 Hz) or 2750 RPM (60 Hz) to match either power grid frequency without hardware changes.

Ball Bearing Construction

Ball bearings replace bushing-style designs for quieter operation and longer service intervals in continuous-duty use.

Automatic Overload Protection

Built-in thermal overload protector shuts the motor down if temperature exceeds safe limits, then resets automatically once cooled.

Class B Insulation

Class B rated windings handle sustained operating temperatures up to 266 deg F (130 deg C), providing a meaningful safety margin for HVAC duty cycles.

Replaces and Cross-References

This motor is the current production replacement for the following part numbers:

  • Dayton 4C826 (direct replacement)
  • NBK Parts 20533 (same unit, alternate catalog number)

If your system currently carries one of those part numbers on the motor nameplate or service manual, the 1TDU8 is the correct replacement.

Drop-In Fit: Shaft diameter (12 mm), overall housing dimensions, and inlet/outlet geometry match the 4C826 exactly. No adapter plates or custom wiring are required for a standard swap.

Inlet and Outlet Geometry

Proper airflow depends on matching the scroll housing interface precisely. The 1TDU8 uses a 2-1/2 in inlet diameter and a 4-5/8 in wide by 1-5/8 in tall outlet -- dimensions that align with the ductwork and housing collars designed around the 4C826. The blower wheel itself measures 2-7/8 in diameter by 3.7 in wide.

Max Inlet Temperature: Incoming air at the blower inlet must not exceed 104 deg F (40 deg C). Sustained higher inlet temps can shorten motor life even with automatic overload protection active.

Installation Tips

  • Disconnect and lock out power before removing the old motor.
  • Note the rotation direction of the existing wheel before disassembly -- confirm the 1TDU8 rotation matches before tightening the set screw on the 12 mm shaft.
  • Verify the blower wheel is fully seated and balanced before reinstating power.
  • If the system previously tripped on overload repeatedly, inspect the ductwork for blockages before installing the new motor.
Maintenance Note: Ball bearing motors do not require routine oiling. Inspect the wheel annually for debris buildup, which increases load and reduces motor life.

Electrical Specifications

Voltage115V AC
Frequency50/60 Hz
Amperage0.45A (50 Hz) / 0.60A (60 Hz)
RPM2600 (50 Hz) / 2750 (60 Hz)
Insulation ClassClass B
Overload ProtectionAutomatic thermal reset

Airflow Specifications

Airflow (CFM)223 CFM
Max Inlet Air Temp104 deg F (40 deg C)

Overall Dimensions

Overall Width14-3/4 in
Overall Height4-3/4 in
Overall Depth3-5/8 in
Weight6 lbs

Housing Dimensions

Housing Height4.8 in
Housing Width3.6 in
Housing Depth4.4 in

Inlet / Outlet / Wheel Dimensions

Inlet Diameter2-1/2 in
Outlet Width4-5/8 in
Outlet Height1-5/8 in
Wheel Diameter2-7/8 in
Wheel Width3.7 in
Shaft Diameter12 mm

Bearing and Construction

Bearing TypeBall bearings
LubricationPre-lubricated, maintenance-free

Part Number Cross-Reference

Dayton Part Number1TDU8
ReplacesDayton 4C826
NBK Catalog Number20533
Important Information
  • This motor operates on 115V AC only -- do not connect to 230V circuits without a step-down transformer.
  • Maximum inlet air temperature is 104 deg F (40 deg C). Exceeding this limit voids the thermal overload protection assumptions and can cause premature failure.
  • Confirm rotation direction before securing the blower wheel to the 12 mm shaft. Reversed rotation will dramatically reduce airflow and may damage ductwork components.
  • Always disconnect power before installation or removal. The automatic overload reset means the motor can restart unexpectedly after a thermal trip.
  • The blower wheel is not included -- this listing covers the motor assembly only. Reuse the existing wheel if it is undamaged, or source a matching 2-7/8 in x 3.7 in wheel separately.