Home > Appliances > Air Conditioners >

Furrion FACT11MA-PS Chill RV AC Ceiling Assembly Manual Control R410A Systems

Furrion FACT11MA-PS Chill RV air conditioner ceiling assembly with manual control knobs and 2-way adjustable airflow louvers for R410A systems
Furrion Chill RV AC Ceiling Assembly, Manual Control, R410A Systems
 
Alternative Views:


List Price: $173.19
: $167.95
You save $5.24!
Part Number: FACT11MA-PS
Manufacturer: Furrion

Quantity in Stock :25

Free Shipping
Availability: In Stock
Qty:

 
Furrion R410A Compatible Ducted + Non-Ducted Furrion FACT11MA-PS -- Chill RV AC Ceiling Assembly, Manual Control

The interior half of your Furrion Chill system -- replace a damaged or failed ceiling assembly without pulling the rooftop unit. Built-in manual knobs put full control in your hand without requiring a wall thermostat, making this a straightforward drop-in for older-generation Furrion Chill R410A installations.

Direct Replacement for Furrion Chill Ceiling Units

When your Furrion Chill rooftop AC is working fine but the interior ceiling assembly has cracked, lost a blower motor, or damaged its control board, the FACT11MA-PS lets you swap just the indoor section. No need to remove the rooftop condenser or reclaim refrigerant -- this is strictly the ceiling-mount evaporator and blower housing that installs from inside the coach.

Manual knob operation means the thermostat and fan speed are dialed in directly on the unit itself. There is no wall control harness to run and no smart-home pairing required -- ideal for older rigs or simplified electrical setups.

Manual Knob Control

Thermostat and fan speed controlled directly on the unit. No wall thermostat wiring required.

3 Fan Speeds

Low, medium, and high blower settings for precise comfort across varying outside temps.

2-Way Adjustable Airflow

Directional louvers let you aim cooled air toward seating or sleeping areas as needed.

Dual Detachable Filters

Two removable air filters capture dust and debris. Rinse and reinstall -- no replacements to order.

Ducted and Non-Ducted Compatibility

The FACT11MA-PS supports both ducted and non-ducted ceiling installations. In non-ducted mode, conditioned air flows directly out of the ceiling unit into the main living area. In ducted mode, the assembly connects to an existing duct distribution system, routing cool air to multiple vents throughout the coach. Confirm your current duct configuration before ordering to ensure the correct adapter plate is on hand.

No Wall Thermostat? No Problem.

The manual control design on the FACT11MA-PS is intentional. Older Furrion Chill installations did not include a digital wall controller, and this assembly matches that original configuration exactly. If you want to upgrade to digital or app-based control, Furrion offers separate controller-compatible ceiling assemblies -- but if you want a like-for-like swap, this is the correct unit.

Installation Overview

The ceiling assembly mounts to the standard 14-inch RV roof opening from inside the coach. The unit is designed to accommodate roof thicknesses from 3 inches up to 6 inches, covering the range found in most fiberglass and aluminum-framed RV roofs. The electrical connection mates to the rooftop condenser unit via the existing wiring harness -- no new wiring runs are typically needed when replacing a like-for-like Furrion Chill ceiling assembly.

  • Install from inside the coach -- rooftop unit stays in place
  • Mates to existing Furrion Chill R410A rooftop condenser wiring
  • Ceiling opening: 14 inches (standard RV AC cutout)
  • Roof thickness range: 3 inches to 6 inches
  • Filters slide out for cleaning without tools

R410A Refrigerant Systems Only

This ceiling assembly is designed and rated for use with R410A refrigerant. It is not compatible with older R22 systems or with the newer R32/low-GWP platforms. Verify your rooftop unit's refrigerant type on the compressor nameplate before purchasing.

Filter Maintenance Tips

Rinse the two mesh filters every 30 days of heavy use or at the start of each cooling season. Allow filters to dry completely before reinstalling -- a wet filter reduces airflow and can transfer moisture into the blower housing. Filters are retained by simple clips and do not require tools to remove.

Pairing with the Correct Rooftop Unit

The FACT11MA-PS ceiling assembly pairs with Furrion Chill rooftop AC units in the older-generation R410A product family, including models sold under the FAC series prefix. If your rooftop unit is a current-generation Furrion Chill with an integrated digital control or Bluetooth connectivity, verify the correct ceiling assembly part number before ordering -- the connectors and control protocols differ between generations.

Part Identification

ManufacturerFurrion
Part NumberFACT11MA-PS
SKU2021123818
UPC4897023263262
Product LineChill RV Air Conditioner
Component TypeIndoor Ceiling Assembly

System Compatibility

Refrigerant TypeR410A only
Compatible SystemFurrion Chill older-generation rooftop AC (R410A series)
Control TypeManual knob (on-unit thermostat and fan speed)
Wall Thermostat RequiredNo
Smart/App ControlNot supported on this assembly

Physical Specifications

Roof Opening14 inches (standard RV AC cutout)
Roof Thickness Range3 inches to 6 inches
Duct CompatibilityDucted and non-ducted
Filter Quantity2 detachable mesh filters

Air Distribution

Fan Speeds3 (Low / Medium / High)
Airflow Direction2-way adjustable louvers
Air Distribution ModeDirect (non-ducted) or ducted distribution

What Is Included

IncludedCeiling assembly housing, blower motor, manual control assembly, 2 mesh air filters, mounting hardware
Not IncludedRooftop condenser unit, refrigerant, duct adapter (if ducted install), wall thermostat

Important Information

  • This is a ceiling assembly (indoor evaporator/blower unit) only -- it does not include the rooftop condenser, compressor, or any refrigerant.
  • Compatible with R410A refrigerant systems only. Do not install on R22 or R32 systems.
  • Intended for older-generation Furrion Chill rooftop AC units. Confirm your rooftop unit generation and connector type before ordering.
  • Manual control only -- this assembly does not support a wall thermostat, digital controller, or Bluetooth/app pairing.
  • Fits standard 14-inch RV roof openings with roof thickness between 3 and 6 inches. Measure your roof thickness before installation.
  • Do not operate with wet or missing filters -- reduced airflow can cause evaporator icing and blower motor strain.
  • Electrical connection should be made by a qualified technician familiar with RV 120V AC wiring. Ensure shore power or generator is disconnected before beginning installation.


Browse for more RV Accessories in the same category as this item: