Home > Electrical > RV Surge Protection >

Southwire 40141-001 50 Amp Reverse Polarity Automatic Transfer Switch, 120/240V RV Power

Southwire 40141-001 50 Amp Reverse Polarity Automatic Transfer Switch, 120/240V RV Power
Southwire 50 Amp Reverse Polarity Automatic Transfer Switch, 120/240V RV Power
 
List Price: $240.19
: $183.99
You save $56.20!
Part Number: 40141-001
Manufacturer: Southwire

Quantity in Stock :31

Free Shipping
Availability: In Stock
Qty:

 
Southwire 40141-001 50 Amp Reverse Polarity Automatic Transfer Switch, 120/240V RV Power

Southwire 40141-001 50 Amp Reverse Polarity Automatic Transfer Switch, 120/240V RV Power

50 amp automatic transfer switch for 120/240V RV shore power and generator power systems. Provides generator-dominant automatic transfer with reverse polarity and open ground protection, LED fault indication, mechanical interlocking contactors, and power-up time delay.

About the Southwire 40141-001 Transfer Switch

The Southwire 40141-001 is a 50 amp automatic transfer switch designed for RVs with both shore power and onboard generator power. It automatically transfers the RV’s AC power source between shore power and generator power, helping remove the need to manually move power cords between sources.

This model is generator dominant. When both shore and generator power are available, generator power takes priority after the generator has energized and the 30-second delay completes. When generator power shuts down, shore power returns after a short 3-4 second delay.

🔁 Automatic Transfer

Automatically switches between RV shore power and generator power

⚡ 50A 120/240V

Designed for 50 amp RV electrical systems using 120/240V service

🛡️ Reverse Polarity Protection

Provides reverse polarity and open ground protection while on shore power

💡 LED Fault Indicator

Includes LED indication for reverse polarity and open ground protection

Key Features & Benefits

  • 50 Amp Automatic Transfer Switch: Transfers RV power between shore power and generator power sources
  • 120/240V RV Electrical Use: Designed for 50 amp RV electrical systems with split-phase service
  • Generator Dominant Operation: Transfers to generator power after a 30-second delay when generator power is available
  • Shore Power Return Delay: Returns to shore power after approximately 3-4 seconds when generator power shuts down
  • Reverse Polarity Protection: Helps protect the RV from unsafe reverse polarity conditions on shore power
  • Open Ground Protection: Helps detect unsafe open ground conditions before allowing shore power operation
  • LED Indicator: Provides visual indication for reverse polarity and open ground protection conditions
  • Mechanical Interlocking Contactors: Helps prevent shore and generator contactors from engaging at the same time
  • Dual Contactor Arrangement: Built for automatic switching between two AC power sources
  • No Surge Protection: This model does not provide surge suppression or full EMS-style protection

🚐 Common RV Applications

The Southwire 40141-001 is commonly used in motorhomes, fifth wheels, and other RVs with a 50 amp shore power connection and onboard generator. It is intended for hardwired installation between the RV’s shore power input, generator output, and main electrical distribution panel.

This model is a transfer switch, not a transformer or amperage converter. It does not convert 30 amp service to 50 amp service and does not provide surge suppression.

Technical Specifications

Part Number 40141-001
Brand Southwire / Surge Guard
Product Type Automatic RV transfer switch
Voltage Rating 120/240V AC
Amp Rating 50 amps
Frequency 60 Hz
Power Sources Shore power and generator power
Transfer Type Automatic
Source Priority Generator dominant
Generator Transfer Delay Approx. 30 seconds after generator power is energized
Shore Power Return Delay Approx. 3-4 seconds after generator shuts down
Protection Features Reverse polarity and open ground protection
Indicator LED indicator for reverse polarity and open ground protection
Surge Protection No
Contactor Arrangement Dual contactor arrangement with mechanical interlocking contactors
Contactor Rating 50A FLA
Mounting Type Hardwire / surface mount installation
Dimensions Approx. 8.48" W x 10.75" H x 5.19" D
UPC 032886731662
Warranty Limited 1-year warranty commonly listed

📦 What's Included

• One Southwire 40141-001 50 amp automatic transfer switch
• Installation documentation as supplied by manufacturer

📋 Installation Notes

This transfer switch is hardwired between the RV’s shore power input, generator output, and main AC distribution panel. Verify 50 amp service rating, 120/240V wiring, conductor size, neutral/ground routing, generator compatibility, enclosure space, and strain relief requirements before installation.

This model does not include surge protection. If surge, low/high voltage, open neutral, miswired pedestal, or full EMS-style protection is needed, use a separate surge/EMS device or choose a Southwire transfer switch model that specifically includes those protections.

⚠️ Electrical Safety

Transfer switch installation involves 120/240V AC power, shore power, generator power, high-current wiring, neutral/ground routing, and RV electrical code requirements.

Installation should be performed by a qualified RV technician or electrician familiar with 50 amp RV electrical systems. Disconnect shore power, generator power, inverter power, and battery power before servicing.

Transfer Switch Replacement Checklist

Check Before Ordering Why It Matters
RV Service Rating
This transfer switch is rated for 50A 120/240V RV electrical systems
Power Sources
Designed to transfer between shore power and onboard generator power
Generator Priority
Generator power dominates when both shore and generator power are present
Protection Level
Provides reverse polarity and open ground protection but does not provide surge protection
Mounting Space
Approximate enclosure dimensions are 8.48" W x 10.75" H x 5.19" D
Wiring Layout
Shore input, generator input, output, neutral, and ground wiring must match the transfer switch installation requirements
Qualified Installation
Improper installation can cause shock, fire, generator damage, or RV electrical system damage

The Southwire 40141-001 is a 50 amp, 120/240V automatic RV transfer switch with reverse polarity and open ground protection. It is not a transformer adapter and does not provide surge protection. Verify service rating, generator compatibility, protection needs, mounting space, and wiring before ordering.