Fasco A079 Draft Inducer Blower Motor 115V 2420/2500 RPM Replaces Rheem York Nordyne

Fasco A079 Draft Inducer Blower Motor 115V 2420/2500 RPM replacement for Rheem York Nordyne furnaces, 3.3-inch diameter shaded pole motor
Fasco Furnace Draft Inducer Blower Motor, 115V, 2420/2500 RPM
 
List Price: $182.00
: $100.49
You save $81.51!
Part Number: A079
Manufacturer: Fasco

Quantity in Stock :35

Free Shipping
Availability: In Stock
Qty:

 
Fasco115V / 2420-2500 RPMUL and CSA ListedFasco A079 Replacement Draft Inducer Blower Motor -- 115V, 2420/2500 RPM

A direct-fit replacement draft inducer blower motor engineered to restore proper combustion air flow in a wide range of residential and light-commercial furnaces. This motor cross-references to Rheem, York, Nordyne, Goodman, Janitrol, Trane, Packard, and Universal part numbers, making it one of the most versatile inducer motor replacements on the market. Built-in thermal overload protection and Class B insulation deliver reliable, long-service operation.

Restore Furnace Draft with a Proven OEM-Cross Replacement

The draft inducer motor is the heart of your furnace's venting system. It pulls combustion gases through the heat exchanger and out the flue before the burner ignites, ensuring safe, efficient operation. When this motor fails -- or runs at reduced speed -- the furnace pressure switch trips, the burner won't light, and heat stops. Replacing it with the correct motor restores normal pressure-switch operation and safe venting.

The Fasco A079 (also catalogued as NBK Parts 12168 and Packard 82483) is a shaded-pole, open-frame motor with a 3.3-inch diameter frame, sleeve bearings, and a 24-inch lead pre-wired with one stripped end and one flag terminal for fast reconnection. The rectangular blower outlet matches the original housing geometry on supported furnace brands.

Wide Cross-Reference

Replaces 19+ part numbers across Rheem, York, Nordyne, Goodman, Janitrol, Trane, Packard, and Universal -- one part covers many furnace platforms.

Built-In Thermal Protection

Integrated thermal overload automatically cuts power if the motor overheats, protecting the furnace control board and wiring from secondary damage.

Pre-Wired for Fast Swap

24-inch lead with one stripped wire and one flag terminal matches original wiring harness connections without splicing or extra adapters.

UL and CSA Listed

Independently certified to UL and CSA standards, meeting safety requirements for furnace replacement components in residential and commercial installations.

Direct OEM Cross-Reference

This motor is a verified replacement for the following part numbers:

  • Fasco A079
  • Fasco 7021-5004
  • Packard 82483
  • Rheem 70-21496-00
  • Rheem 70-21496-03
  • Rheem 70-21496-06
  • Rheem 70-21504-03
  • Rheem 70-21504-04
  • Rheem 7021-7481
  • Rheem 74-70-21496-03
  • Rheem 74-70-21504-03
  • Trane MOT-3482
  • Universal 577
  • Universal 9438
  • Goodman B1859000
  • Janitrol B1859000
  • Nordyne RH702149603
  • Nordyne RH702149683
  • York 026-32067-000
  • York 026-32067-700
  • NBK Parts 12168
Motor Construction Details

The shaded-pole motor design is the industry standard for draft inducer applications because it requires no starting capacitor, has no brushes to wear, and is tolerant of the dusty, high-temperature environments inside a furnace cabinet. The open-frame enclosure allows the motor windings to dissipate heat efficiently during continuous-duty operation. Sleeve bearings are pre-lubricated for long service life and are well-suited to the fixed-orientation mounting common in inducer assemblies.

Installation Tips
  • Before removing the original motor, photograph the wiring and blower wheel orientation so you can match them on the replacement.
  • The blower wheel is typically retained by a set screw -- note the wheel depth on the original shaft before pulling it off; install the replacement wheel to the same depth.
  • Confirm the rotation direction on the original motor label matches this unit (check the Fasco A079 spec sheet for CW/CCW designation).
  • After installation, run the furnace through two full heat cycles and verify the pressure switch closes normally before returning the unit to service.
  • Always shut off power and gas to the furnace before beginning any motor replacement.
Also Known As

This motor is listed and sold under multiple catalog numbers depending on the distributor: NBK 12168, Packard 82483, and Fasco 7021-5004 all refer to the same unit as the Fasco A079. If you sourced your original part under one of those numbers, this is the correct replacement.

Electrical Specifications

Voltage115V AC
Current Draw0.43 / 0.52 amps
Frequency50/60 Hz
PhaseSingle phase
Motor TypeShaded pole
Insulation ClassClass B
Thermal ProtectionBuilt-in automatic overload

Performance Specifications

Speed2420 / 2500 RPM
Blower Outlet ShapeRectangle
Ambient Temperature Rating104 deg F (40 deg C)

Physical Specifications

Frame Diameter3.3 inches
Bearing TypeSleeve bearing
Motor EnclosureOpen
Lead Length24 inches
Lead Termination1 stripped end, 1 flag terminal
Weight5 lbs

Certifications and Listings

Safety ListingsUL Listed, CSA Listed

Part Number Cross-Reference

FascoA079, 7021-5004
NBK Parts12168
Packard82483
Rheem70-21496-00, 70-21496-03, 70-21496-06, 70-21504-03, 70-21504-04, 7021-7481, 74-70-21496-03, 74-70-21504-03
York026-32067-000, 026-32067-700
NordyneRH702149603, RH702149683
Goodman / JanitrolB1859000
TraneMOT-3482
Universal577, 9438
Important Information
  • Always disconnect electrical power and shut off the gas supply to the furnace before beginning motor replacement. Failure to do so is a serious shock and fire hazard.
  • Verify your existing motor's part number, voltage, RPM, and rotation direction before ordering. Incorrect rotation will prevent the pressure switch from closing and may cause carbon monoxide to vent improperly.
  • The blower wheel is NOT included -- reuse the original wheel from your furnace or order separately. Confirm wheel bore and set-screw size before installation.
  • This motor is rated for a maximum ambient temperature of 104 deg F (40 deg C). Do not install in environments exceeding this rating.
  • Built-in thermal protection will trip if the motor is blocked or operating in an over-temperature condition -- investigate and correct the root cause before resetting.
  • This is a furnace-grade replacement motor intended for residential and light-commercial forced-air heating applications. It is not rated for outdoor exposure or submersion.


Browse for more RV Accessories in the same category as this item: