Home > Home & Marine Upgrades > Blower Motors >

Dayton 1TDT6 2-Speed Blower Motor 428/293 CFM 1500/1085 RPM 115V Replaces 4C565

Dayton 1TDT6 2-speed blower motor 428/293 CFM 1500/1085 RPM 115V replacement for Dayton 4C565 NBK 20500
Dayton 2-Speed Blower Motor, 428/293 CFM, 1500/1085 RPM, 115V
 
List Price: $158.49
: $113.49
You save $45.00!
Part Number: 1TDT6
Manufacturer: Dayton

Quantity in Stock :36

Free Shipping
Availability: In Stock
Qty:

 
Dayton428/293 CFMClass B InsulationDayton 1TDT6 2-Speed Blower Motor -- 428/293 CFM, 1500/1085 RPM, 115V

A direct replacement for the Dayton 4C565 blower motor, the 1TDT6 delivers reliable two-speed airflow in HVAC, heating, and ventilation equipment. Pre-matched dimensions and shaft size mean a straightforward swap with no modification required. Also cross-referenced as NBK Parts 20500.

Direct Drop-In Replacement for Dayton 4C565

When your original blower motor fails, the 1TDT6 restores full two-speed operation without sourcing a custom or OEM-priced unit. At high speed it moves 428 CFM at 1500 RPM; drop it to low speed and output steps down to 293 CFM at 1085 RPM -- ideal for applications that need quiet circulation or reduced airflow on demand.

Ball bearings support both speeds efficiently, and automatic thermal overload protection shuts the motor down before heat damage can occur. Class B insulation keeps it running safely in warm equipment cabinets. Counter-clockwise (CCW) shaft rotation matches the original 4C565 wheel orientation so the existing blower wheel and housing bolt straight on.

Two-Speed Airflow

High: 428 CFM at 1500 RPM. Low: 293 CFM at 1085 RPM. One motor covers both operating modes.

Ball Bearing Construction

Precision ball bearings provide longer service life and quieter operation versus sleeve-bearing alternatives.

Automatic Overload Protection

Built-in thermal overload cuts power if the motor overheats, protecting the motor and connected equipment.

Direct Replacement Fit

Replaces Dayton 4C565. Matched shaft diameter, rotation, and flange dimensions eliminate guesswork.

Verified Replacement Cross-Reference

This motor is a direct replacement for Dayton model 4C565 and is also sold under the NBK Parts number 20500. Confirm your original motor's rotation (CCW) and voltage (115V) before ordering.

Rotation and Wheel Compatibility

The 1TDT6 rotates counter-clockwise when viewed from the inlet side. If your existing installation uses a CW-rotation motor, this unit will not be a direct swap. Check the nameplate on your current motor before purchasing.

Max Inlet Temperature: 104 deg F

Do not install this motor in supply-air applications where intake air temperature can exceed 104 deg F (40 deg C). It is rated for return-air and circulation duty at or below that threshold.

Installation Tips
  • Disconnect and lock out power before removing the old motor.
  • Note all wiring connections on the original motor before disconnecting -- photograph the terminal block if needed.
  • The 8 mm shaft diameter is metric; confirm your blower wheel hub bore before reusing the existing wheel.
  • Verify flange mounting bolt pattern against your housing before final installation.
  • Run the motor briefly at low speed first to confirm correct rotation before buttoning up the cabinet.

Electrical Specifications

Voltage115V AC
Frequency60/50 Hz
Amperage1.1A
Speeds2 (High / Low)
Insulation ClassClass B
Overload ProtectionAutomatic thermal overload

Performance Specifications

CFM (High Speed)428 CFM
CFM (Low Speed)293 CFM
RPM (High Speed)1500 RPM
RPM (Low Speed)1085 RPM
RotationCounter-Clockwise (CCW)
Max Inlet Temperature104 deg F (40 deg C)

Physical Dimensions

Overall Height9-3/8 in
Overall Width9-1/4 in
Overall Depth8-1/2 in
Inlet Diameter4-1/2 in
Outlet Height3-1/2 in
Outlet Width7-3/4 in
Flange Size9-7/16 in W x 5 in H
Shaft Diameter8 mm
Weight6 lbs

Blower Wheel Specifications

Wheel Diameter5-1/8 in
Wheel Width7 in
Bearing TypeBall bearings

Part Number Cross-Reference

Dayton Part Number1TDT6
ReplacesDayton 4C565
NBK Parts Number20500
Important Information
  • This motor operates on 115V AC only -- do not attempt to run on 12V DC or 230V without a verified matching unit.
  • Rotation is counter-clockwise (CCW) only. Using a CCW motor in a CW application will reverse airflow direction and may damage equipment.
  • Maximum inlet air temperature is 104 deg F. Exceeding this limit voids any warranty and risks motor failure.
  • The blower wheel is NOT included -- this listing is for the motor only. Reuse your existing compatible wheel or source separately.
  • Always de-energize and lock out the circuit before installation. This motor is not a plug-and-play appliance -- hardwired installation by a qualified technician is recommended.
  • Confirm shaft diameter (8 mm metric) compatibility with your existing blower wheel hub before installation.