Home > Home & Marine Upgrades > Blower Motors >

Fasco A217 Draft Inducer Blower Motor 208-230V 3000 RPM Replaces Lennox 25M5501 7021-11231

Fasco A217 furnace draft inducer blower motor 208-230V 3000 RPM replacement for Lennox 25M5501 and Fasco 7021-11231
Fasco Furnace Draft Inducer Blower Motor For Fasco/Lennox, 208-230V, 3000 RPM
 
List Price: $185.89
: $102.49
You save $83.40!
Part Number: A217
Manufacturer: Fasco

Quantity in Stock :34

Free Shipping
Availability: In Stock
Qty:

 
Fasco 208-230V / 3000 RPM Direct Replacement Fasco A217 Furnace Draft Inducer Blower Motor -- Replaces Lennox 25M5501 and Fasco 7021-11231

This Fasco A217 draft inducer blower motor is a factory-spec replacement for select Fasco and Lennox gas furnaces. Running at 3000 RPM on 208-230V single-phase power, it restores proper combustion air management and venting performance. Ball bearing construction, built-in thermal protection, and Class B insulation make it a durable, long-service drop-in repair part. Also catalogued under NBK Parts number 12170.

Restore Proper Draft and Combustion Performance

A failing draft inducer motor is one of the most common causes of furnace lockout, pressure switch faults, and incomplete ignition sequences. This Fasco A217 motor pulls combustion gases through the heat exchanger and out the flue before and during burner operation -- a critical function in induced-draft and direct-vent gas furnace designs.

Designed to match the original Fasco OEM motor used in Lennox furnaces, this replacement restores correct airflow rates, pressure switch operation, and venting efficiency without modification. The 15-inch leads with spade terminals connect directly to existing furnace wiring harnesses on the models listed below.

Ball Bearing Construction

Ball bearings provide longer service life and quieter operation compared to sleeve bearing alternatives, especially in continuous or high-cycle furnace duty.

Built-In Thermal Protection

Integrated thermal overload protection automatically shuts the motor down if it overheats, protecting the furnace control board and heat exchanger.

Class B Insulation

Class B winding insulation is rated for continuous operation in furnace environments up to 130 deg C winding temperature rise, well suited to hot-area mounting.

Ready-to-Connect Leads

15-inch leads with spade terminals match OEM wiring length and connector style, making reconnection straightforward on covered models.

Fitment and Compatibility

This motor is a verified direct replacement for the following part numbers:

  • Fasco 7021-11231
  • Lennox 25M5501
  • Lennox 7021-11231
  • NBK Parts 12170 (cross-reference)

Always verify your existing motor's voltage, RPM, rotation direction, and mounting configuration against the specs listed here before ordering. Lennox and Fasco furnaces using this inducer motor are typically found in the G series and related single-stage upflow and horizontal configurations -- confirm your model number against the part numbers above.

Direct Drop-In Replacement: Matches OEM voltage (208-230V), RPM (3000), frame diameter (3.3 inches), and lead length (15 inches with spade terminals) for covered models. No wiring modifications or adapter brackets required.

Installation Notes

Draft inducer motors are mounted to the inducer housing assembly, which is secured to the furnace vestibule panel. On most Lennox applications using this motor:

  • Disconnect power to the furnace at the breaker and service switch before beginning.
  • Label or photograph the existing wiring before disconnecting spade terminals.
  • The inducer housing typically unbolts from the flue collar and vestibule panel -- inspect the gasket for damage and replace if needed (gasket not included).
  • The motor mounts to the inducer housing with screws through the motor flange; transfer the impeller wheel from the old motor shaft to the new motor shaft, confirming correct rotation direction.
  • Verify impeller is fully seated and set-screw is tightened before reinstalling the housing assembly.
Rotation Direction: Confirm the rotation direction of your existing motor (CW or CCW when viewed from the shaft end) before installing. Incorrect rotation will move air in the wrong direction through the inducer housing and can cause nuisance pressure switch faults or inadequate venting.
Impeller Not Included: This listing covers the motor only. The inducer impeller/wheel is not included. Reuse the original impeller from your existing motor if it is undamaged, or source the correct replacement impeller separately.
Maintenance Tip: While the inducer assembly is apart, inspect the flue transition boot, pressure switch tubing, and condensate drain port (if applicable) for cracks, blockages, or deterioration. Addressing these items during the same service call prevents repeat callbacks.

Electrical Specifications

Voltage208-230V AC
Frequency60 Hz
PhaseSingle phase
Current Draw0.36A
Motor TypeShaded pole
Insulation ClassClass B
Thermal ProtectionBuilt-in (automatic reset)

Mechanical Specifications

Speed3000 RPM
Frame Diameter3.3 inches
Bearing TypeBall bearing
EnclosureOpen air over (OAO)
Lead Length15 inches
Lead TerminationSpade terminals
Weight5 lbs

Environmental Ratings

Max Ambient Temperature104 deg F (40 deg C)
Insulation Temp ClassClass B (130 deg C winding rise)

Part Number Cross-Reference

Fasco ModelA217
Fasco OEM Part7021-11231
Lennox Part Number25M5501
Lennox Alt Part7021-11231
NBK Cross-Reference12170
Vendor Part Number12170

What Is Included

Draft Inducer MotorYes -- 1 unit
Inducer Housing/ScrollNot included
Impeller WheelNot included
Mounting HardwareNot included
Flue GasketNot included
Important Information
  • Always disconnect power at the breaker and furnace service switch before servicing the draft inducer assembly. Capacitors and live terminals may be present.
  • Verify rotation direction (CW or CCW shaft end) matches your existing motor before final installation. Installing a motor with incorrect rotation will not vent combustion gases properly and may create a safety hazard.
  • This motor is rated for a maximum ambient temperature of 104 deg F (40 deg C). Do not install in locations where ambient temps exceed this rating.
  • The impeller/blower wheel is not included. Inspect your existing wheel carefully before reuse -- a cracked or imbalanced wheel will shorten motor bearing life.
  • Verify your furnace model and existing motor part number (typically on a label on the motor housing) match the listed cross-references before installation.
  • This product is intended for use in residential and light commercial gas furnace applications by qualified HVAC technicians. Local codes may require a licensed contractor for furnace repair.


Browse for more RV Accessories in the same category as this item: