Home > LP Gas > LP Adapters >

Camco 59113 4-Port Propane Tee -- Female POL, Soft Nose POL, 1-Inch Female, 1/4-Inch Inverted Flare

Camco 59113 4-Port Propane Tee with female POL, excess flow soft nose POL, 1-inch female, and 1/4-inch inverted flare fittings for RV motorhomes
Camco 4 Port Propane Tee
 
Alternative Views:


List Price: $85.19
: $65.99
You save $19.20!
Part Number: 59113
Manufacturer: Camco

Quantity in Stock :21

Availability: In Stock
Qty:

 
Camco Part # 59113 1-Year Warranty Camco 4-Port Propane Tee -- Model 59113

Expand your motorhome LP system with a single inline fitting. The Camco 59113 installs between your onboard supply and regulator to simultaneously support an auxiliary propane cylinder and an additional high-pressure appliance -- no extra hardware required beyond the hoses you already own or can add separately.

One Fitting, Four Connections -- More Options at Camp

Motorhomes with a permanently installed LP tank are limited by their factory plumbing. The Camco 59113 breaks that bottleneck by splitting your propane supply into four independently usable ports. You can run your coach appliances off the main tank while simultaneously tapping an auxiliary cylinder or running a portable high-pressure appliance off the dedicated 1/4-inch inverted flare port.

The tee accepts both ACME (new-style) and P.O.L. (old-style) connections, so it works with hoses and regulators you likely already own. The soft-nose excess flow POL port adds a layer of safety -- the excess flow valve shuts down automatically if downstream flow exceeds a safe rate, such as in a hose rupture event.

Auxiliary Tank Ready

Soft nose excess flow POL port lets you connect a standard external propane cylinder to supplement your permanently installed tank.

Appliance Port Included

Dedicated 1/4-inch inverted flare outlet supports high-pressure hose connections for grills, camp stoves, and lanterns.

Disposable Cylinder Compatible

The 1-inch female port accepts standard 1-lb disposable cylinder threads, giving you a quick connect for small portable appliances.

Dual Connection Standard Support

Compatible with both ACME (new-style) and P.O.L. (old-style) fittings so it works with legacy and modern RV hose assemblies.

Inline Installation -- No Cutting Required

The 59113 installs directly in the propane supply line between your tank and regulator. The female POL inlet threads onto your existing LP supply connection. No special tools or soldering are needed. Hoses for the auxiliary ports are sold separately -- choose the length and type that suits your campsite setup.

Great for Tailgating and Boondocking

When you are parked without hookups or running your generator heavily, connecting an auxiliary tank to the 59113 extends your LP runtime significantly. Run your furnace, water heater, and fridge off the main tank while a grill or camp stove draws from the auxiliary cylinder.

Port-by-Port Breakdown

  • Port 1 -- Female POL: Inlet connection to your motorhome's existing LP supply line (old-style P.O.L. thread).
  • Port 2 -- Excess Flow Soft Nose POL: Output port for an auxiliary propane cylinder; includes built-in excess flow safety feature.
  • Port 3 -- 1-Inch Female (Acme/disposable): Accepts standard disposable 1-lb cylinder threads or new-style ACME fittings for portable appliances.
  • Port 4 -- 1/4-Inch Inverted Flare: High-pressure appliance port for tabletop grills, camp stoves, or lanterns via a compatible high-pressure hose.
Hoses Sold Separately

The Camco 59113 tee body is sold alone. You will need to purchase compatible LP hoses and/or adapters separately to complete your setup. Camco offers a full line of matching propane hoses and accessories.

Fitment and Application

This tee is designed specifically for motorhomes with a permanently installed propane tank. It is not intended as a standalone regulator or for use with RVs that use only 1-lb disposable cylinders as a primary source. Common applications include:

  • Class A, B, and C motorhomes with an in-line LP supply between tank and regulator
  • Adding a portable auxiliary cylinder for extended boondocking
  • Connecting a tabletop grill, camp stove, or propane lantern without a separate dedicated line
  • Any installation where the supply line uses a standard female POL fitting at the connection point
Installation Tips
  • Always shut off the main LP valve before installing or removing the tee.
  • Use an approved thread sealant (LP-rated, not standard Teflon tape) on all threaded connections.
  • Leak-test all joints with soapy water or an LP-approved leak detector solution after installation before relighting any appliances.
  • Ensure hose connections are fully hand-tightened, then snugged with a wrench -- do not overtighten brass fittings.
  • Store unused ports with appropriate caps when not in use to prevent debris contamination.

Product Identification

ManufacturerCamco
Camco Part Number59113
SKU / Store Code66-8910
Vendor Part Number06-0476
UPC014717591133
Warranty1 year
Quantity per Order1 tee fitting

Port Specifications

Port 1 (Inlet)Female POL (P.O.L. old-style)
Port 2 (Auxiliary Tank)Excess flow soft nose POL
Port 3 (Disposable / ACME)1-inch female (disposable cylinder / ACME new-style)
Port 4 (Appliance)1/4-inch inverted flare (high-pressure)
Total Ports4

Compatibility

Primary ApplicationMotorhomes with permanently installed LP tank
Connection StandardsACME (new-style) and P.O.L. (old-style)
Auxiliary Tank TypeStandard refillable propane cylinders (via POL connection)
Disposable CylinderStandard 1-lb threaded disposable cylinders (Port 3)
Appliance TypesTabletop grills, camp stoves, lanterns (high-pressure hose required)

What Is Included

Included1x Camco 59113 4-port propane tee body
Not IncludedLP hoses, adapters, regulators (sold separately)

Safety Features

Excess Flow ProtectionYes -- on soft nose POL port (Port 2)
Excess Flow FunctionShuts flow automatically if downstream rate exceeds safe limit (e.g., hose rupture)
Important Safety Information
  • Propane is a flammable gas under pressure. Installation must be performed by a qualified technician if you are not experienced with LP gas systems.
  • Always turn off the main LP supply valve at the tank before making any connections or disconnections.
  • Leak-test every fitting with an approved LP leak detection solution after installation -- never use an open flame to check for leaks.
  • Do not use standard white PTFE plumber's tape on LP fittings; use only yellow LP-rated thread sealant tape or approved pipe dope.
  • The excess flow valve on Port 2 may temporarily restrict flow if the downstream appliance draws gas too quickly when first opened -- open valves slowly to allow the excess flow device to reset.
  • Cap unused ports to prevent contamination and accidental discharge.
  • Not for use with high-pressure systems downstream of the tee without confirming appliance and hose pressure ratings.
  • Hoses are sold separately -- do not use damaged, cracked, or non-LP-rated hoses with this fitting.


Browse for more RV Accessories in the same category as this item:

LP Gas > LP Adapters
LP Gas