Step 1: Install Hi-Flow shut off valve to inlet.
Note: The softener does not require salt or regeneration when received. Unit Contains Cation Exchange Resin which is either light gold or light amber to black spherical beads. DO NOT REMOVE.
Step 3: Replace cap, remove outlet hose and rinse very slowly.
Step 4: Increase water flow to fast-rinse.
Note: Follow specifications listed for each separate model.
General Instructions: Use your water quality test strips to check the water hardness of the water source to predict capacity of the unit. Use your water quality test strips to check outlet stream to determine when to perform the next regeneration cycle or use calendar regenerated method as described above. During regeneration process only discharge water (containing salt and mineral concentration) into a drain.
Back flush your Standard Softener every 3 months for 2-5 minutes, Double Standard Softener for 5-10 minutes and 10-15 minutes for the Park Model by connecting water source to softener outlet and turning water on full stream.
Note: If Back-flush and Re-gen are done together, perform Back-flush first.
You can use either of these two options if draining water from unit is required. In both options DO NOT REMOVE top cap.
Before placing in storage or being idle for extended periods
1st - Perform Back-Flush
2nd - Regenerate
3rd - Drain Water from Unit
After extended periods of non use, sanitize unit by 1st - Performing Back Flush, 2nd - slow rinsing unit with 1/4th cup of bleach for the Standard Model and 2/4 cup of bleach for the Double Standard Model, 3rd - Perform complete regeneration.
GENERAL INFORMATION:
A. REGENERATING OPTIONS:See brochure for detailed description of hardness and calendar regenerating methodsB. CAPACITY OF UNIT:Use your water quality test strips to check the water hardness of the water source to predict capacity of the unit.C. EXTREMELY HARD WATER CONDITIONS:Add 2 Tbs of Super Iron Out in addition to the salt. [found @ Wal-mart or hardware stores]D. BACK-FLUSH OF UNIT: