INSTALLATION INSTRUCTIONS Thetford Bravura
A. Remove front cover at base of stool. A. Remove two bolts, one on each side. B. Remove water line located at the rear of stool. ( MAKE SURE WATER IS OFF )
A. Remove front cover at base of stool.
A. Remove two bolts, one on each side. B. Remove water line located at the rear of stool. ( MAKE SURE WATER IS OFF )
A. Flush Line enters back of stool going to the bowl. B. Cut line about half way. C. Install T-valve with arrow pointed toward the bowl. D. With the clamps provided, secure T-valve in place. [Photo View 1]
A. Flush Line enters back of stool going to the bowl.
B. Cut line about half way.
C. Install T-valve with arrow pointed toward the bowl.
D. With the clamps provided, secure T-valve in place. [Photo View 1]
View 1
A. Locate reservoir to the back or side wall, providing easy access for filling. B. Keep reservoir lower than the stool. [Photo View 2] C. Screw reservoir into place with three screws provided with kit.
A. Locate reservoir to the back or side wall, providing easy access for filling.
B. Keep reservoir lower than the stool. [Photo View 2] C. Screw reservoir into place with three screws provided with kit.
View 2
A. Check water lines for leaks. B. Check stool by flushing. C. Add a few ounces of Blue Streak Chemical® to reservoir. D. Flush stool. Finish filling reservoir.
A. Check water lines for leaks. B. Check stool by flushing. C. Add a few ounces of Blue Streak Chemical® to reservoir.
D. Flush stool. Finish filling reservoir.
A: Run the chemical level low [1to 2 inches] in the reservoir and winterize your unit as you would normally. To remove chemical from the reservoir; unscrew the tank from the wall leaving tubing attached to tank and pour chemical into another container.