INSTALLATION INSTRUCTIONS
Thetford Aria (2003 and Newer)
Single Vacuum Breaker Model |
|
1. Remove the stool. |
A. Remove two bolts,
one on each side.
B. Remove the water line located at the rear of stool.
(MAKE SURE WATER IS OFF).
C. Unhook wires to stool.
|
|
2. Locate flush line
between vacuum breaker and bowl.
A. Cut the flush
line half way between vacuum breaker and bowl. [Photo
View 1]
B. Insert T-valve with small arrow pointing toward the
bowl. [Photo View 2]
THIS IS VERY IMPORTANT
(T-valve will not work if installed backwards)
C. With the two hose clamps enclosed in kit secure
T-valve in place. [Photo View 3]
|
[View 1] |
[View 2] |
[View 3] |
|
3. Reinstall stool
making sure all gaskets, bolts and water connections are
secure. Reattach the wires. |
|
4. Mounting the
dispenser reservoir to the wall. |
A. Locate reservoir
to the back or side of the wall providing easy access
for filling.
B. Keep level or lower than back of stool.
C. Screw reservoir into place with the three screws
provided.
|
|
5. FINAL CHECK LIST |
A. Check water line
for leaks.
B. Check stool by flushing.
C. Add a few ounces of Blue Streak Chemical to
reservoir.
D. Flush stool. Finish filling reservoir.
|
|
6. Q: How do
I winterize the Blue Streak Dispenser? |
A:
Run the chemical level low [1to 2 inches]
in the reservoir and winterize your unit as you would
normally. To remove chemical from the reservoir; unscrew
the tank from the wall leaving tubing attached to tank
and pour chemical into another container.
|