Home > Lippert Repair Parts > Slide-Out Motors and Actuators >

Lippert 28:1 Venture Actuator Slide-Out Motor
Lippert 136373 28:1 Venture Actuator Slide-Out Motor
Lippert 28:1 Venture Actuator Slide-Out Motor
 
Alternative Views:


Price: $486.84
MFG P/N: 136373
MFG: Lippert
UPC #: 711217012983
SHIPS: 1 Business Day

Quantity in Stock :24

Free Shipping
Availability: In Stock
Qty:

Description Instructions
 
The Lippert 136373 is a replacement 28:1 Venture motor designed for electric 2 x 2 or 2.5 x 2.5 through frame slide-out systems.
  • Voltage: 12V DC.
  • Amps: 30A.
  • RPM: 5,800.
  • 2-1/2" inner gear.
  • Manufacturer Reference Number: 8532-08J
  • Keystone RV Part Number: 410180
  • Winnebago Part Number: 2T059000039
  • Weight: 5 lbs.

Lippert 28:1 Venture Actuator Slide-Out Motor

Additional Product Information
TROUBLESHOOTING MOTOR
Before attempting to troubleshoot the Motor, make sure an adequate power source is available. The unit batteries should be fully charged or the unit should be plugged into to A/C service with batteries installed.

Do not attempt to troubleshoot the Motor without assuring a full 12V DC charge

The following tests require only a DC voltmeter (or DC test light) and a jumper lead.
Step 1 - Attach voltmeter (or test light) leads to the negative and positive switch terminals on back of wall switch (See Fig. 10). Does the meter indicate 12V DC?
If YES, see Step 2; if NO see Step 3.
Step 2 - If YES, at the motor, check the incoming leads to 12V DC (if necessary, disconnect leads at wire splices). Does meter indicate 12V DC?
If YES, Motor needs to be replaced. The motor is not field serviceable. DO NOT ATTEMPT TO REPAIR.
If NO, Inspect all wires and connections between the wall switch and the motor. Repair connections as necessary. Recheck as in Step 1.

Step 3 - If NO, Inspect all connections between battery and switch.

Inspect 30A Auto-reset Circuit Breaker (See Fig. 10 for location).

Recheck as above in Step 1.

Since there are no field serviceable parts in the motor, electrical troubleshooting and service is limited to replacing only those components as previously outlined.

Thorough inspection of wiring and connections is the only other electrical service that can be performed.